Evaluate: MAX1400/MAX1402
MAX1402 Evaluation Kit/Evaluation System
8
_______________________________________________________________________________________
Table 4. Guide to Register Bit Functions
REGISTER
BIT NAME
DESCRIPTION
COMMS
0/DRDY
Start bit is zero; DIN pin must be 1 when idle
RS2–RS0
Register select for subsequent operation
R/
W
Selects subsequent read or write operation
RESET
Causes software reset when set to 1
STDBY
Activates standby power-down mode when set to 1
FSYNC
Inhibits the A/D converter when set to 1
GS1
A1
Selects the active channel
A0
Selects the active channel
MF1
Selects the data output rate
MF0
Selects the data output rate
CLK
Selects the CLKIN frequency
FS1
Select the data output rate
FS0
Select the data output rate
FAST
Selects SINC
1
filter instead of SINC
3
GS2
SCAN
Enables the scanning sequences
M1
Enables the CalGain channel
M0
Enables the CalOff channel
BUFF
Enables the input buffers
DIFF
Selects differential input pairs
BOUT
Enables the transducer burn-out test currents
IOUT
Enables the OUT1 and OUT2 current sources (MAX1402 only)
X2CLK
Selects the CLKIN frequency
SFR
MDOUT
Changes the DOUT and
INT
pins to provide raw modulator output
FULLPD
Activates full power-down mode. Use hardware reset to restore normal operation.
All other bits in SFR must be zero
TF1, 2, 3
G2–G0
Select the PGA Gain
U/
B
Selects unipolar or bipolar coding
D3–D0
Select the offset correction DAC code; D3 = sign, D2–D0 = magnitude
DATA
D17–D0
Raw code value
DS1
Value of the DS1 input pin (MAX1402 only)
DS0
Value of the DS0 input pin (MAX1402 only)
CID2–CID0
Channel identification tag