![Maxim DS33R11 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/maxim/ds33r11/ds33r11_user-manual_1744312059.webp)
DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
59 of 344
Figure 9-6. DS33R11 Configured as a DCE in MII Mode
MAC
TXD[3:0]
RXD[3:0]
TX_CLK
RX_CLK
TX_ERR
RX_ERR
TX_EN
RX_CRS
COL_DET
COL_DET
DTE
DCE
TX_EN
RXDV
MDC
MDIO
TXD[3:0]
RXD[3:0]
TX_CLK
DS33Z11
MAC
RX_CLK
RXDV
RX_CRS
MDIO
MDC
Rx
Tx
Tx
Rx
9.15 Ethernet MAC
Indirect addressing is required to access the MAC register settings. Writing to the MAC registers requires the
SU.MACWD0
-3 registers to be written with 4 bytes of data. The address for the write operation must be written to
SU.MACAWL
and
SU.MACAWH
. A write command is issued by writing a zero to
SU.MACRWC
.MCRW and a one
to SU.MACRWC.MCS (MAC command status). MCS is cleared by the DS33R11 when the operation is complete.
Reading from the MAC registers requires the
SU.MACRADH
and
SU.MACRADL
registers to be written with the
address for the read operation. A read command is issued by writing a one to SU.MACRWC.MCRW and a zero to
SU.MACRWC.MCS. SU.MACRWC.MCS is cleared by the DS33R11 when the operation is complete. After MCS is
clear, valid data is available in SU.MACRD0-SU.MACRD3. Note that only one operation can be initiated (read or
write) at one time. Data cannot be written or read from the MAC registers until the MCS bit has been cleared by the
device. The MAC registers are detailed in the following table.