4. Press the scan button to auto-detect the Smart Sensor board that shows as PPG under
"Connected Devices".
5. Click "Launch Tool" to run the MAXREFDES220#-specific features.
6. Configure the PPG settings as desired. Do not change the FIFO settings from their
default values.
7. Select “Accelerometer Data” to display X-axis and Y-axis accelerometer results from the
Sensor Board.
8. Select “Algorithm Data” to display the data from the IR and red LED sensors.
Updating the MAX32630FTHR firmware
These steps are only necessary if the MAX32630FTHR does not initialize as described
above.
1. Navigate to the Maxim Integrated website, enter MAXREFDES220# into the search tool.
Select the entry for MAXREFDES220# in the Product Results section.
2. From the product page, select Design Resources and download the files under
"Firmware Files".
3. Extract the .bin file into any directory.
4. Connect one end of the ribbon cable to the black header J4 on the MAX32630FTR.
5. Examine the other end of the ribbon cable carefully. One side of the cable going into the
black header SWD is marked by the red wire. Connect the cable and SWD header,
making sure the red wire is furthest from the letters SWD.
6. Connect a mini USB cable between the USB connector labeled HDK and the PC.
7. Open a File Explorer window. The programming adapter shows as a new USB drive.
8. Drag and drop the downloaded .bin file onto the icon for the new USB drive. The LED
begins to flash red while the MAX32630FTHR is being programmed.
9. When the LED stops flashing, remove the ribbon. Press the reset button on the
MAX32630FTHR and verify the operation of the MAX32630FTHR
Part Number
MAXREFDES220#
Status
Active
Carrier Type
Box
https://www.maximintegrated.com/en/design/reference
‐
design
‐
center/system
‐
board/6657.html/tb_tab0
8
‐
6
‐