STLEP1OUT
Meaning:
Stall EP1-OUT. Return the STALL handshake in response to an OUT request to
endpoint 1.
Location:
EPSTALLS.2
Set:
The CPU sets this bit to instruct the SIE to return the STALL handshake for an
OUT request directed to endpoint 1.
Clear:
The CPU clears this bit to return EP1-OUT to normal ACK-NAK operation.
POR:
STLEP1OUT=0
Chip Reset:
STLEP1OUT=0
Bus Reset:
STLEP1OUT=0
Pwr Down:
Read-only
Programming Notes:
The CPU sets this bit when it receives a Set_Feature(HALT) directed to EP1-OUT.
The CPU clears this bit when it receives a Clear_Feature(HALT) directed to EP1-OUT.
61