MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
hi_rng
8
0
W1C
ADC Sample Above High Limit Interrupt Flag
Set by hardware when a collected ADC sample is out of range on the high side (above the programmable hi_limit threshold).
Write 1 to clear.
ADC_INTR.lo_rng
Field
Bits
Default
Access
Description
lo_rng
9
0
W1C
ADC Sample Below Low Limit Interrupt Flag
Set by hardware when a collected ADC sample is out of range on the low side (below the programmable lo_limit threshold).
Write 1 to clear.
ADC_INTR.done
Field
Bits
Default
Access
Description
done
10
0
W1C
ADC Data Collection Complete Interrupt Flag
Set by hardware when an ADC data collection cycle has completed.
Write 1 to clear.
ADC_INTR.fifo_uf
Field
Bits
Default
Access
Description
fifo_uf
11
0
W1C
ADC FIFO Underflow Interrupt Flag
Rev.1.3 April 2015
Maxim Integrated
Page 438
Содержание MAX32600