MAX32600 User’s Guide
Analog Front End
8.2 AFE Reconfiguration Matrix
Selects hysteresis magnitude setting for comparator.
• 00b: 0mV
• 01b: 7.5mV
• 10b: 15mV
• 11b: 30mV
AFE_CTRL2.hyst_comp_d
Field
Bits
Default
Access
Description
hyst_comp_d
7:6
00b
R/W
Low-Power Comparator D Hysteresis Magnitude
Select
Selects hysteresis magnitude setting for comparator.
• 00b: 0mV
• 01b: 7.5mV
• 10b: 15mV
• 11b: 30mV
AFE_CTRL2.hy_pol_comp_a
Field
Bits
Default
Access
Description
hy_pol_comp_a
8
0
R/W
Low-Power Comparator A Hysteresis Polarity
Select
Selects hysteresis polarity setting for comparator.
• 0: Vp
>
Vn+Vhys
Rev.1.3 April 2015
Maxim Integrated
Page 377
Содержание MAX32600