Quick Reference Guide
Dedicated Micros 2060
The type 2060 can be controlled via RS 485 commands or ‘up the co-ax’.
With RS 485 control each dome has to individually addressed using the Blue and Yellow rotary
address switches following the address chart on the previous page. For ‘up the co-ax’ control, using
the built in protocol converter, the same address switches are used to select the protocol format for
the controller being used e.g.
BAX AC PANEL
Blue. F Yellow. C = 252
For: Baxall a.c. controllers
DEN PANEL
Blue.F Yellow. D = 253
For: Dedicated Micros, BBV & DM Sprite controllers
BAX DC PANEL
Blue.F Yellow. D = 254
For: Baxall d.c. controllers
For ‘up the co-ax’ control using external protocol converters like the drx 100 or DAX-DEN the address
swtiches should be set to Blue.0 Yellow.1 = 1.
To access the address swtiches remove the outer hemisphere and inner shroud as shown in A & B.
Picture C shows the location. This operation should be carried out in an office type environment to
avoid ingress of moist air.