44
45
EN
Option 4.3 - Connecting an ICU charging station
Connect the UTP cable to the Ethernet
port of the charging station and the
ETH port of Maxem.
It is possible to update the charging station firmware. This can be done via ICU
Connect, as soon as the charging station is online. ICU Alfen can assist you with this.
It is advisable to test the network cable with the help of a cable tester.
Data activity on
ETH port ICU
UTP cable with RJ45 connectors
D.
REVISION
TITLE:
A4
DWG NO.
SCALE:1:2
SHEET 1 OF 2
WEIGHT:
A
A
B
B
C
C
D
D
E
E
F
F
4
4
3
3
2
2
1
DATE
SIGNATURE
DO NOT SCALE DRAWING
MATERIAL:
NAME
1
DRAWN
LINEAR:
CHK'D
APPV'D
MFG
Q.A
ANGULAR:
FINISH:
TOLERANCES:
EDGES
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
DEBURR AND
BREAK SHARP
Maxem5-R4
Install a circuit breaker and/or earth leakage circuit breaker for each
charging station at the maximal power available
. See p. 33.
Follow the installation instructions of the charging station. These
instructions can be found in the installation manual of the charging
station.
Place a suitable UTP (CAT5 or CAT6) cable from the charging station to Maxem and
clench RJ45 connectors on both sides.
A.
B.
C.
Data activity on ETH
port Maxem
ETH poort voor
laadstation
REVISION
TITLE:
A4
DWG NO.
SCALE:1:2
SHEET 1 OF 2
WEIGHT:
A
A
B
B
C
C
D
D
E
E
F
F
4
4
3
3
2
2
1
DATE
SIGNATURE
DO NOT SCALE DRAWING
MATERIAL:
NAME
1
DRAWN
LINEAR:
CHK'D
APPV'D
MFG
Q.A
ANGULAR:
FINISH:
TOLERANCES:
EDGES
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
DEBURR AND
BREAK SHARP
Maxem5-R4
05 - Commissioning by installer
Without proper commissioning Maxem is unable to send a current limiting value
to the charging station. This results in OVER CURRENT OF THE GRID CONNECTION.
Therefore always make sure this step is successful.
Turn on the charging station or restart it by taking off the current for 30 sec. and
putting it back on. Wait at least 1 minute for the charging station to start up. This way
you know that the charging station has fully started up.
Connect the 230V power supply to Maxem.
A.
B.
Maxem has to be configured online by the installer in order to be commissioned.
For this go to the (mobile) website:
https://install.maxem.io
D.
In case of problems during commissioning, you can contact Maxem support:
+31 20 7708 713
Input: 110 - 240V ~ 0,5A
50/60Hz Max 2,75W
Serial number:
CAT III
Made in The Netherlands.
Registration key:
8
719326
026800
MX4-1-H-000000
0000
Serial number
Registration key
Serial number and registration key can be found on the back side of Maxem.
Wait until the first 3 status LED’s on Maxem are green. This means that Maxem is
connected to the network, the internet and the data cloud.