5.3.  SPYDER PARAMETER TYPES 

 

Calibration parameters

 - these values are dependent on Spyder hardware.  These include sensor calibration, 

input / output calibrations, etc.  These parameters are only valid for the Spyder from which they were received. 
 

Data parameters

 - these values are not dependent on Spyder hardware.  These include Stop Time, Start Time,  

Tension Units, etc.  Data parameters may be sent to any Spyder to create a copy of a Spyder. 
 
The Spyder web page shows whether a parameter is a Data or Calibration parameter.  The Spyder user manual 
also shows whether a parameter is a Data or Calibration parameter and additionally shows the minimum and 
maximum of each parameter. 
 
 

5.4.  SAVE SPYDER PARAMETERS TO A FILE 

 
Press the "Spyder to PC" button to transfer parameters to a file.  A file dialog box will be displayed to choose the 
file.  All of a Spyder's parameters are saved in the file.  A "Transfer Complete" message box will be displayed if no 
errors occurred. 
 
 

5.5.  GET SPYDER PARAMETERS FROM A FILE 

 
Select the type of parameters to transfer either Data Only, Calibration Only, or both Data and Calibration.  Press 
the "PC to Spyder" button to transfer the parameters to the Spyder.  A file dialog box will be displayed to choose 
the file containing the parameters.   A "Transfer Complete" message box will be displayed if no errors occurred. 
 
 

6. 

TROUBLESHOOTING 

 

 

 

Problem 

Possible Cause 

Solution or Diagnostic 

Spyder List is blank. 

Computer or Spyder 
network parameters not 
set properly. 

 

Check Computer and Spyder 
network parameters, IP Address 
and Subnet Mask.  Cycle Spyder 
power after changing network 
parameters. Restart Windows 
operating system. 

Missed refresh of list. 

Wait 10 seconds for list to refresh 
after the Spyder has booted. 

Ethernet cable not 
connected or hub/switch 
not powered. 

Check Ethernet connection(s). 

 

Spyder(s) not powered. 

Computer ARP table 
corrupt. 

Verify Spyder(s) have power. 

From a DOS prompt type:             
arp -d 

Transfer Failed 

Spyder not in Hold or 
Manual or Security is Set. 

Put Spyder in Hold or Manual.  
Unsecure the Spyder. 

 

 

 

 

 

 

 

 

NORTH, CENTRAL 

AND SOUTH AMERICA 

Tel +1.360.834.2345 

Fax +1.360.834.5865 

sales@maxcessintl.com 

www.maxcessintl.com 

EUROPE, MIDDLE EAST 

AND AFRICA 

Tel +49.6195.7002.0 

Fax +49.6195.7002.933 

sales@maxcess.eu 

www.maxcess.eu

 

CHINA 

 

Tel +86.756.881.9398 

Fax +86.756.881.9393 

info@maxcessintl.com.cn 

www.maxcessintl.com.cn

 

 

INDIA 

 

Tel +91.22.27602633 

Fax +91.22.27602634 

india@maxcessintl.com 

www.maxcess.in

 

JAPAN 

 

Tel +81.43.421.1622 

Fax +81.43.421.2895 

japan@maxcessintl.com 

www.maxcess.jp

 

KOREA, TAIWAN, 

AND SE ASIA 

Tel +65.9620.3883 

Fax +65.6235.4818 

asia@maxcessintl.com 

 

 

 

 

 

© 2013 Maxcess 

Отзывы: