background image

2-3 

SAFETY INSTRUCTIONS 

 

www.maxcessintl.com 

MAGPOWR TS Load Cell 

MI 850A342 1 A 

 

Basic safety 
information 

Proper use 
The load cell devices are intended to be used on machines or 
systems to monitor the tension in a web. 
Indoor operation. 
 
Improper use 
Operation outside the technical specifications 

Operation in an Ex-area or intrinsically safe area without a 
proper barrier. 

Any other use than the proper use shall be deemed inappropriate 
 
Installation and commissioning 
Any load cell device that is damaged must not be installed or put 
into operation. 

Only perform installation, maintenance or repair tasks on the 
load cell device when the machine has been stopped and is 
secured from being turned on. 

Only perform installation, maintenance or repair tasks on the 
load cell device when there is no electrical power in the system. 

The load cell device must be securely mounted before being 
placed in operation. 

No modifications may be made to the load cell device. 

Do not place electrical cables under mechanical strain. 
 
Maintenance and repair 
Warning – Danger of injury from crushing 
Maintenance and repair tasks on the load cell device must be 
performed only when the machine has been stopped and has 
been secured from being turned on again. 
 
Decommissioning 
The load cell must be disposed of in accordance with all the 
applicable national, state and local regulations. 
 

 

 

 

 

Содержание MAGPOWR TS Load Cell

Страница 1: ...MAGPOWR TS Load Cell User Manual EN EC 12 connector type MI 850A342 A MAGPOWR TENSION CONTROL...

Страница 2: ...ommissioning 2 3 Maintenance and repair 2 3 Decommissioning 2 3 INSTALLATION 3 1 General 3 1 Stud mount 3 1 Flange mount 3 1 Pillow block mount 3 1 Shaft and roll assembly 3 2 Split coupling models 3...

Страница 3: ...tly Completed Machinery into a machine or partly completed machine The instructions must be read and used by all persons who have the responsibility of installing and maintaining these load cell devic...

Страница 4: ...e and the need to recalibrate even after extreme overloads A full Wheatstone bridge arrangement of four foil strain gages is used in each sensor for the most accurate means of measuring web tension In...

Страница 5: ...uration supports the customer s dead or live shaft on each side of the machine The In Roll configuration supports the customer s roll assembly hollow tube on each side of the machine The Wire Pulley c...

Страница 6: ...of these operating instructions Any safety instructions on the device The machine manufacturer s specifications All national state and local requirements for installation accident prevention and envi...

Страница 7: ...s that may result in bodily injuries or damage to device or material WARNING CAUTION Danger due to crushing Reference to danger of injury caused by crushing WARNING CAUTION Danger due to cutting Refer...

Страница 8: ...tenance or repair tasks on the load cell device when the machine has been stopped and is secured from being turned on Only perform installation maintenance or repair tasks on the load cell device when...

Страница 9: ...line of the sensor so that it bisects the wrap angle of the web If the orientation of the sensor requires the force direction arrow to be pointed opposite the resultant tension force direction then th...

Страница 10: ...ed behind the removable part of the split coupling Remove the coupling screws and top half of the couplings Gently lower the shaft roller assembly into the couplings The couplings have some misalignme...

Страница 11: ...periodic lubrication of the bearing on the live shaft rotating coupling and in roll applications A grease fitting is located on the top of the coupling for the split coupling models and under the o r...

Страница 12: ...oupling type Connector type Units type Sxx Series TS Tension sensor Load rating in pounds English units models in kilograms Metric units models Mounting type S Stud F Flange P Pillow block Coupling ty...

Страница 13: ...or TS330PC EC12 TS330PR EC12 TS330PW EC12 Pillow Block Mount 500 lb Sensor TS500PC EC12 TS500PR EC12 TS500PW EC12 Metric Stud Mount 2 Kg Sensor TS2SC EC12M TS2SR EC12M TS2SW EC12M Metric Stud Mount 10...

Страница 14: ...C12M TS10SC EC12M TS25SC EC12M TS75SC EC12M TS150SC EC12M TS250SC EC12M Flange mount models TS5FC EC12 TS25FC EC12 TS50FC EC12 TS150FC EC12 TS330FC EC12 TS500FC EC12 TS2FC EC12 TS10FC EC12 TS25FC EC12...

Страница 15: ...2 63 1 63 2 93 5 25 0 50 3 18 TS500PC EC12 2 60 4 11 1 250 2 50 1 05 0 500 4 00 2 2 0 50 2 73 2 00 2 00 2 63 1 63 2 93 5 25 0 50 3 18 Metric stud mount split coupling models units are in millimeters w...

Страница 16: ...2M TS10SC EC12M TS25SR EC12M TS75SR EC12M TS150SR EC12M TS250SR EC12M Flange mount models TS5FR EC12 TS25FR EC12 TS50FR EC12 TS150FR EC12 TS330FR EC12 TS500FR EC12 TS2FR EC12M TS10FR EC12M TS25FR EC12...

Страница 17: ...5 25 0 50 0 79 3 18 TS500PR EC12 2 60 2 97 2 44 0 76 0 500 4 00 2 2 0 50 1 59 2 00 2 00 2 63 1 63 2 93 5 25 0 50 0 79 3 18 Metric stud mount in roll models units are in millimeters weight in kilogram...

Страница 18: ...C12M TS10SW EC12M TS25SW EC12M TS75SW EC12M TS150SW EC12M TS250SW EC12M Flange mount models TS5FW EC12 TS25FW EC12 TS50FW EC12 TS150FW EC12 TS330FW EC12 TS500FW EC12 TS2FW EC12M TS10FW EC12M TS25FW EC...

Страница 19: ...5 25 0 50 1 19 2 70 TS500PW EC12 2 60 2 93 2 70 0 57 0 500 4 00 2 2 0 50 1 55 2 00 2 00 2 63 1 63 2 93 5 25 0 50 1 19 2 70 Metric stud mount wire pulley models units are in millimeters weight in kilo...

Страница 20: ...ature 30 C to 80 C 22 F to 176 F Temperature effect on zero 0 02 of rating per C 01 of F Combined non linearity and hysteresis 0 5 of full scale maximum Repeatability 0 2 of full scale maximum Overloa...

Страница 21: ...ensstrasse 13 15 48683 Ahaus Deutschland NORTH CENTRAL AND SOUTH AMERICA Tel 1 405 755 1600 Fax 1 405 755 8425 sales maxcessintl com www maxcessintl com EUROPE MIDDLE EAST AND AFRICA Tel 49 6195 7002...

Отзывы: