4-1 

INSTALLATION 

 

www.maxcessintl.com 

MAGPOWR GTS Load Cell 

MI 850A347 1 A 

 

Mechanical and 
electrical installation 

 

 

 

CAUTION – Possible damage to load cell. 
Do not hammer on the load cell. 

 

 

CAUTION – Possible damage to load cell. 
Do not disassemble the load cell – there are no 
serviceable parts inside the unit. 

 

 

WARNING – Danger of injury from crushing. 
Maintenance and repair tasks on the load cell device 
must be performed only when the machine has been 
stopped and has been secured from being turned on 
again. 

 

 

1.

 

Select a mounting location where the wrap angle of 
the web does not change. 

2.

 

GTS load cells are designed to be mounted under 
standard, self-aligning pillow block bearings, 
which support an idler roll shaft. Two GTS load 
cells should be used to measure tension on one 
idler roll. Mount the load cells on opposite sides of 
the machine, on a clean and flat surface of the 
machine frame. The load cells can be mounted in 
any orientation. 

3.

 

Observe the wrap angle of the web, and insure that 
the resultant force due to web tension is in the 
“YES” zone as indicated on the label. If not, turn the 
load cell around and recheck the direction of the 
resultant force. 
NOTE:  If the resultant force is “upward” (away from 
the load cell), reverse the black (-s) and white (+s) 
signal leads at the readout or control terminal 
block. 

Figure 1. Typical Load Cell Usage 

 

Figure 2. Load Cell Wiring 

 

1

2

3

4

Содержание MAGPOWR GTS Load Cell

Страница 1: ...MAGPOWR GTS Load Cell User Manual EN MI 850A347 1 A MAGPOWR TENSION CONTROL...

Страница 2: ...ey 2 2 Available models 2 3 Selection and sizing 2 4 SAFETY INSTRUCTIONS 3 1 Instructions for use 3 1 Symbols used 3 2 Proper use 3 3 Installation and commissioning 3 3 Maintenance and repair 3 3 Deco...

Страница 3: ...ned and manufactured to be installed as Partly Completed Machinery into a machine or partly completed machine The instructions must be read and used by all persons who have the responsibility of insta...

Страница 4: ...The load cell construction consists of a beam with a metal foil strain gage bonded at the bending point of the beam The spring constant of the beam causes the beam to deflect with the applied force T...

Страница 5: ...ng GTSA22 EC12 22 lbs GTSA55 EC12 55 lbs GTSA110 EC12 110 lbs GTSB220 EC12 220 lbs GTSB550 EC12 550 lbs GTSB1100 EC12 1100 lbs GTSB2200 EC12 2200 lbs Metric series Force rating GTSA10 EC12M 10 kg GTSA...

Страница 6: ...load cells NOTES Angle B cannot exceed 45 The second term roll weight W 2 of the equation must not exceed 50 of the selected load cell rating If it does exceed 50 select the next larger load cell rati...

Страница 7: ...t of these operating instructions Any safety instructions on the device The machine manufacturer s specifications All national state and local requirements for installation accident prevention and env...

Страница 8: ...s that may result in bodily injuries or damage to device or material WARNING CAUTION Danger due to crushing Reference to danger of injury caused by crushing WARNING CAUTION Danger due to cutting Refer...

Страница 9: ...ntenance or repair tasks on the load cell device when the machine has been stopped and is secured from being turned on Only perform installation maintenance or repair tasks on the load cell device whe...

Страница 10: ...load cells are designed to be mounted under standard self aligning pillow block bearings which support an idler roll shaft Two GTS load cells should be used to measure tension on one idler roll Mount...

Страница 11: ...aft expansion 6 The sensing roll must be concentric and balanced for high speed operation 7 Connect the load cell to the MAGPOWR readout or control with shielded cable GTSA M GTSB M Maximum bolt penet...

Страница 12: ...r kits Due to the large number of metric pillow blocks and in keeping with metric practices mounting adapter kits are available for the metric series load cells Order one kit for each load cell Load c...

Страница 13: ...tap holes with the Adapter Kit installed on the load cell TA1 and TA2 Installation The TA1 and TA2 T Slot Adapter kits can be installed on any GTSAM load cell 1 Position the 2 T Slot rails over the 4...

Страница 14: ...perature 30 C to 80 C Temperature effect on zero 0 02 of rating per C Combined non linearity and hysteresis 0 5 of full scale maximum Repeatability 0 2 of full scale maximum Overload stops 105 to 150...

Страница 15: ...lb GTSB M 3 4 kg 7 5 lb TA1 0 14 kg 0 3 lb TA2 0 18 kg 0 4 lb TA3 0 9 kg 1 9 lb Cable Connector 12B222 1 MAGPOWR mating cable assembly Part LCC5M or mating connector Part 12B220 1 pin 1 power pin 2 s...

Страница 16: ...www maxcess eu Siemensstrasse 13 15 48683 Ahaus Deutschland AMERICAS Tel 1 405 755 1600 Fax 1 405 755 8425 sales maxcessintl com www maxcessintl com EUROPE MIDDLE EAST AND AFRICA Tel 49 6195 7002 0 F...