Fife H3257
MI 1-921 1
Operation
LED intensity settings
The H3257 functions as a stand-alone light source using
factory calibrated light intensity/profile settings.
Factory calibration sets the drive level of each LED to the
same value for each of eight profile settings.
Intensity
setting
Relative LED
drive level
1
30%
2
40%
3
50%
4
60%
5
70%
6
80%
7
90%
8
100%
(default)
Table 3. H3257 intensity settings
Intensity setting versus
sensor gap
* Harsh or very dusty environments may require a higher
intensity setting.
(Keep the lens clean.
See
Maintenance; page 5-1.)
Gap (sensor to light source)
Intensity setting
2 feet [61 cm] or less
2*
Greater than 2 feet [61 cm]
8
When used with the H3109 Discriminating Detector, the
intensity must be set to level 8.
See page 3-4