COMMISSIONING
6 - 2
D-MAXE with OI-TS
www.maxcessintl.com
MI 2-292 1 C
To commission the D-MAXE system, make the basic settings
described in the following steps.
Note:
If the system documentation contains "D-MAXE Supplementary
Operating Instructions" with a chapter on Commissioning, the
commissioning sequence given there must be followed for the
specific application.
1. Turn on the electrical power
When the system is turned on, the last operating mode to be
selected is active.
2. Select the language
It may be necessary to change the language for menu
guidance on the operator interface.
see menu
3. Select drive (device)
see menu
Note:
Each drive must be set separately.
4. Take over
Local Control
If the parameter
Local Control
is set to "...limited", it needs
to be set to "...taken over".
5. Select Manual mode
Switch the D-MAXE system into Manual mode with the
button 1 on the operator interface.
There is no guiding of the web course in Manual mode. The
D-MAXE System control parameter can now be configured.
6. Set the sensor type
Check and set the type of the connected sensor(s).
7. Calibrate sensor(s)
Calibrate the connected sensor/sensors.
1y.5.1.1.1 Calibration, page 7-12
8. Calibrate
LineSpeed
If the LineSpeed parameter is being used, this parameter
must be calibrated.
see menu