SCREEN DEFINITIONS
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 56 of 66
Screen Function
Definition
Voltage on TB6-2
Display of the voltage present corresponding to the load
cell signal input. This is useful for evaluating the
performance of load cells by comparing actual vs.
expected return signal for a given applied force.
Sensor Voltage
Display of actual voltage present at the sensor input
terminal
Web Velocity
Select to enter calibration of an external web speed
sensor. Web speed sensor input must be active; see
also CONFIGURE I/O
Web Width___
Select to edit the current web width for use in tension
setpoint calculation when TENSION UNITS of PLI,
kg/cm, gm/mm, oz/in, or N/cm are selected. Also used
for changing INERTIA values.
Weightless calibration
Select to calibrate load cells without using weights. This
procedure depends on correct entries for the LOAD
CELL RATING and WRAP ANGLE to provide accurate
readings
Width ___
Enter a value for the web width
Wrap angle
Enter a value for the wrap angle formed by the web
around the sensing roll. Example: A web that comes
straight up, wraps around the roll, and continues straight
down is a 180 degree wrap. A web that comes straight
up, wraps around the roll, and continues on to the right
is a 90 degree wrap.
Содержание Cygnus MAGPOWR