P/N 08023027 RevB Page 1
2272PB-100
Double Hood
User Instructions
CAUTION
Before use, thoroughly read MAXAIR
®
CAPR
®
P/N 03521015 User Instruction (received with all CAPR Helmets
and available at www.maxair-systems.com).
!
WARNING
Failure to follow User Instructions P/N 03521015 and the instructions
contained herein may be hazardous to the user’s health.
Use only if package is received unopened and contents are
undamaged. If damage is noted, contact the shipper for replacement
or repair.
Prior to using any MAXAIR
®
System or component, be sure to be
familiar with the system’s NIOSH approved configuration.
DO NOT use if any component is damaged. If any components are
damaged or contaminated and therefore unfit for safe and effective
use, they should be replaced immediately.
Only trained and experienced personnel who have read and
understand the User Instructions should use MAXAIR Products.
The institution using this product in any application is responsible
for determining the appropriateness of this equipment relative to
regulatory requirements. Bio-Medical Devices Intl, Inc. does not
recommend the appropriate systems for a particular institution or
facility.
Use only MAXAIR Systems/ NIOSH approved compatible
components.
NOT for use in atmospheres immediately dangerous to life or health
(IDLH), and atmospheres containing less than 19.5% oxygen, or
more than 25% oxygen.
Flammability Level I: fabric may burn if exposed to open flame.
Follow current local regulations governing biohazard waste to safely
dispose of single use MAXAIR Products.
If you need more information, contact your BMDI Sales
Representative, or call BMDI customer service at 1-800-443-3842.
!
Intended Use
The MAXAIR CAPR Hood Systems filter aerosolized and droplet
particulates and provide high level fluid resistance when used with a
MAXAIR CAPR Powered Air Purifying Respirator (PAPR) Helmet.
Hoods are designed for single use applications.
Standard CA-CAPR-36 System with 2272PB-100
Double Hood
1. 2081-03 Helmet
(includes 2051-07 SnapOn
Cage, 2071-08 Liner, 2590-05
Power Cord)
2. 2272PB-100 Hood
3. 2061-05 HFR FCC
4. 2500-36TSC Battery*
5. 2000-76 Battery Belt
6. 2600-02 Battery Charger
*Alternate Batteries include the 2500-37TSC.
Regulatory
NIOSH PAPR100-N
1
5
6
2
4
Specifications
Recommended System Temperature Limits
Use/Handling: 0
o
C to 54
0
C at a maximum 80% Relative Humidity.
Charging: 0
o
C to 45
0
C at a maximum 80% Relative Humidity.
Storage: 0
o
C to 35
0
C at a maximum 80% Relative Humidity.
MATERIAL
TYPE
FLUID RESISTANCE
Body (Shroud)
Polypropylene
ASTM F1671
Lens
Polycarbonate
ASTM F1671
Hood Filter
Polypropylene
AATCC TM127
HLF
Polypropylene/
modacrylic blend
General particle filter
material
3
Warning, Caution, or Note
Catalog Number NIOSH Number
!
Symbol Definitions
REF
P/N
2272PB-100SM
(Small-Medium)
08031025
2272PB-100ML
(Medium-Large)
08031026
REF
REF
P/N