background image

P/N 08023027 RevB   Page 1

2272PB-100 

Double Hood

User Instructions

 CAUTION 

 

Before use, thoroughly read MAXAIR

®

 CAPR

®

 P/N 03521015 User Instruction (received with all CAPR Helmets 

and available at www.maxair-systems.com). 

 

      

               

!

              

               

WARNING                                             

Failure to follow User Instructions P/N 03521015 and the instructions 
contained herein may be hazardous to the user’s health.

Use only if package is received unopened and contents are  
undamaged. If damage is noted, contact the shipper for replacement 
or repair.

 

Prior to using any MAXAIR

®

 System or component, be sure to be 

familiar with the system’s NIOSH approved configuration.

 

DO NOT use if any component is damaged.  If any components are 

damaged or contaminated and therefore unfit for safe and effective 

use, they should be replaced immediately.

Only trained and experienced personnel who have read and  
understand the User Instructions should use MAXAIR Products.

 

The institution using this product in any application is responsible 
for determining the appropriateness of this equipment relative to 
regulatory requirements. Bio-Medical Devices Intl, Inc. does not 
recommend the appropriate systems for a particular institution or 
facility.

 

Use only MAXAIR Systems/ NIOSH approved compatible  
components.

 

NOT for use in atmospheres immediately dangerous to life or health 
(IDLH), and atmospheres containing less than 19.5% oxygen, or 
more than 25% oxygen.

Flammability Level I: fabric may burn if exposed to open flame.

 

Follow current local regulations governing biohazard waste to safely 
dispose of single use MAXAIR Products.

If you need more information, contact your BMDI Sales  
Representative, or call BMDI customer service at 1-800-443-3842.

 

      

               

!

Intended Use

 

 

The MAXAIR CAPR Hood Systems filter aerosolized and droplet 

particulates and provide high level fluid resistance when used with a 

MAXAIR CAPR Powered Air Purifying Respirator (PAPR) Helmet.

Hoods are designed for single use applications.

Standard CA-CAPR-36 System with 2272PB-100 
Double Hood

1.  2081-03 Helmet  

(includes 2051-07 SnapOn 
Cage, 2071-08 Liner, 2590-05 
Power Cord)

2. 2272PB-100 Hood 

3. 2061-05 HFR FCC

4. 2500-36TSC Battery*

5. 2000-76 Battery Belt

6. 2600-02 Battery Charger

*Alternate Batteries include the 2500-37TSC.

 

Regulatory 

 

NIOSH PAPR100-N 

 

1

5

6

2

4

Specifications

Recommended System Temperature Limits

 

Use/Handling: 0

o

C to 54

0

C at a maximum 80% Relative Humidity. 

Charging: 0

o

C to 45

0

C at a maximum 80% Relative Humidity. 

Storage: 0

o

C to 35

0

C at a maximum 80% Relative Humidity.

MATERIAL

TYPE

FLUID RESISTANCE

Body (Shroud)

Polypropylene 

ASTM F1671

Lens

Polycarbonate

ASTM F1671

Hood Filter

Polypropylene

AATCC TM127

HLF

Polypropylene/  
modacrylic blend

General particle filter 

material

3

                    
               Warning, Caution, or Note

               Catalog Number              NIOSH Number

 

      

               

!

Symbol Definitions

REF

P/N

         2272PB-100SM

 

         (Small-Medium)

 08031025

         2272PB-100ML

 

          (Medium-Large)

 08031026

REF

REF

P/N

P/N