Appendix 1

:

 Resistance table for indoor/outdoor ambient temperature sensors (numerical value of resistance) (15K) 

Temp. (°C)  Resistance (k

Temp. (°C)  Resistance (k

)

Temp. (°C)

Resistance (k

Temp. (°C) Resistance (k

)

-19 138.100 

20  18.750 59 

3.848  98 

1.071 

-18 128.600 

21  17.930 60 

3.711  99 

1.039 

-17 121.600 

22  17.140 61 

3.579  100 

1.009 

-16 115.000 

23  16.390 62 

3.454  101 

0.980 

-15 108.700 

24  15.680 63 

3.333  102 

0.952 

-14 102.900 

25  15.000 64 

3.217  103 

0.925 

-13 97.400 

26  14.360 65 

3.105  104 

0.898 

-12 92.220 

27  13.740 66 

2.998  105 

0.873 

-11 

87.350 28 

13.160 67 

2.896  106 

0.848 

-10 82.750 

29  12.600 68 

2.797  107 

0.825 

-9 

78.430 30 

12.070 69 

2.702  108 

0.802 

-8 74.350 

31 11.570 

70  2.611 

109 0.779 

-7 70.500 

32 11.090 

71  2.523 

110 0.758 

-6 

66.880 33 

10.630 72 

2.439  111 

0.737 

-5 

63.460 34 

10.200 73 

2.358  112 

0.717 

-4 60.230 

35  9.779 

74  2.280 

113 0.697 

-3 57.180 

36  9.382 

75  2.206 

114 0.678 

-2 54.310 

37  9.003 

76  2.133 

115 0.660 

-1 51.590 

38  8.642 

77  2.064 

116 0.642 

0 49.020 

39 8.297 

78  1.997 

117 0.625 

1 46.600 

40 7.967 

79  1.933 

118 0.608 

2 44.310 

41 7.653 

80  1.871 

119 0.592 

3 42.140 

42 7.352 

81  1.811 

120 0.577 

4 40.090 

43 7.065 

82  1.754 

121 0.561 

5 38.150 

44 6.791 

83  1.699 

122 0.547 

6 36.320 

45 6.529 

84  1.645 

123 0.532 

7 34.580 

46 6.278 

85  1.594 

124 0.519 

8 32.940 

47 6.038 

86  1.544 

125 0.505 

9 31.380 

48 5.809 

87  1.497 

126 0.492 

10 29.900 

49  5.589 

88  1.451 

127 0.480 

11 28.510 

50  5.379 

89  1.408 

128 0.467 

12 27.180 

51  5.197 

90  1.363 

129 0.456 

13 25.920 

52  4.986 

91  1.363 

130 0.444 

14 24.730 

53  4.802 

92  1.282 

131 0.433 

15 23.600 

54  4.625 

93  1.244 

132 0.422 

16 22.530 

55  4.456 

94  1.207 

133 0.412 

17 21.510 

56  4.294 

95  1.171 

134 0.401 

18 20.540 

57  4.139 

96  1.136 

135 0.391 

19 19.630 

 

58 3.990 

 

97 1.103 

 

136 0.382 

 

Содержание BDS28A

Страница 1: ...informative purpose The company declines every responsibility for the results of projecting or installation based on the explanations and the technical specifications given in this manual Is besides...

Страница 2: ...2 Serie Series Serie Serie TECHNICAL MANUAL MONO DC INVERTER Emissione Issue Ausgabe Emission 04 2013 Catalogo Catalogue Katalog Catalogue MTE01028D2505 00 Sostituise Supersade Ersetzt Remplace...

Страница 3: ...r units 10 7 CONTROL FUNCTIONS 11 7 1 Temperature parameters 11 7 2 Basic functions 11 8 TROUBLESHOOTING 15 8 1 Malfunction diagnosis should be performed as below procedure 15 8 2 Confirmation 15 8 3...

Страница 4: ...5 2 1 5 Evaporator Coil length x height x width l x H x L mm 662 x 25 4 x 305 662 x 25 4 x 305 Swing motor model MP24HA MP24HB MP24HC MP24HA MP24HB MP24HC Output of swing motor W 2 4 2 4 Fuse A 3 15...

Страница 5: ...Gas additional charge g m 20 20 Liquid pipe mm 6 6 Outer diameter Gas pipe mm 9 52 9 52 Height m 10 10 Connecting pipe Max distance Length m 15 20 The above data of specifications are subject to chan...

Страница 6: ...ndition Indoor DB27 WB19 Indoor air flow Super High Pipe length 5m 0 20 40 60 80 100 120 140 160 180 200 Outdoor temp Capacity ratio g n i t a e H g n i l o o C Condition Indoor DB20 Indoor air flow S...

Страница 7: ...high Super high 55 Notes 1 Connecting piping condition 5m 2 T1 Outlet and inlet pipe temperature of evaporator T2 Outlet and inlet pipe temperature of condenser P Pressure of air pipe used for connect...

Страница 8: ...U O T I N U R O O D N I HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR GAS SIDE 3 WAY VALVE LIQUID SIDE 2 WAY VALVE COOLING HEATING Accumlator Discharge Suction 4 Way valve Electron expan...

Страница 9: ...OUT 3 2 OUTDOOR UNIT N 1 BN BU XT1 PE L L DC MOTOR M1 ROOM TUBE K7 SWING UD1 AP2 SWING MOTOR TEMP SENSOR TUBE ROOM TEMP SENSOR CAP JUMP 5 2 Outdoor units BDS28A BDS35A 4YV COMP M XT2 RT3 0 0 RT2 0 RT...

Страница 10: ...outdoor units 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 15 Communication interface of indoor and outdoor units 6 2 Outdoor units BDS28A BDS35A No Part name 1 Input of neutral wire of power 2 Input of live...

Страница 11: ...it will maintain its original operating status Under this mode the switchover reversal valve will be de energized and the temperature can be set from 16 C to 30 C If the compressor is shut down for so...

Страница 12: ...air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature When the unit is turned off in HEAT mode or switched to other mode fro...

Страница 13: ...s cleared Total current up and frequency down protection If the total current Itotal W frequency rise will be allowed if Itotal X frequency rise will not be allowed if Itotal Y the compressor will run...

Страница 14: ...f compressor If exhaust temperature 98 C frequency is not allowed to rise If exhaust temperature 103 C the compressor will run at reduced frequency If exhaust temperature 110 C the compressor will sto...

Страница 15: ...the system will memorize the timing function in the latest remote control order after being powered on again and the timing time will be calculated from the power on time again If there is timing fun...

Страница 16: ...oor fan stop while indoor fan operates During heating operation all loads stop Please refer to the malfunction analysis discharge protection overload 5 Overcurrent protection E5 Blinks 5 times Blinks...

Страница 17: ...Blinks 3 times Blinks 6 times During cooling and drying operating compressor stops while indoor fan operates During heating operation the complete unit will stop operation 1 Outdoor ambient temp senso...

Страница 18: ...sed to the normal range 2 If the AC input is normal measure the voltage of electrolytic capacitor C on control panel AP1 if it s normal there s malfunction for the circuit please replace the control p...

Страница 19: ...essor will stop while indoor fan will operate During heating operation the complete unit will stop operation Refer to the malfunction analysis IPM protection loss of synchronism protection and overcur...

Страница 20: ...g and drying operation the compressor will stop while indoor fan will operate During heating operating the complete unit will stop operation There s circuit malfunction on outdoor unit s control panel...

Страница 21: ...contacted Is there short circuit due to trip over of the parts Is the temperature sensor normal according to the resistance table Replace the main board with the same model End Insert the temperature...

Страница 22: ...the blade to make it rotate smoothly Is the malfunction eliminated Is the wiring terminal of PG motor loose Energize and retart up the unit test if the voltage between motor terminal 1 and 2 is 280 31...

Страница 23: ...See the flow chart below C5 is displayed on the unit Is there jumper cap on the mainbaord Install a matching jumper cap Is the jumper cap inserted incorrectly or improperly Is the malfunction eliminat...

Страница 24: ...t and check if the connecting wire of indoor and outdoor unit and wiring of electric box are correct Is wire connected correctly Does the broken down indoor unit resume normal Replace the broken down...

Страница 25: ...op of D304 Bottom of D304 IPM drive voltage 15V 13 5V 15 5V Test 4 Top of C116 bottom of C116 Relay drive voltage 12V 11V 13V Test 5 Right side of R228 left side of D228 PFC drive voltage 15V 13 5V 15...

Страница 26: ...the insulation of compressor coil s against the copper tube is in good condition Switch on the unit and wait 1 minute Use DC voltmeter to measure the voltage on the two ends of electrolytic capacitor...

Страница 27: ...e the capacitor C2 Then energize and start the unit If the unit can work normally Replace the control panel AP1 Please confirm 1 In the indoor and outdoor heat exchangers are obstructed by other objec...

Страница 28: ...the complete unit is powerd off Does the outdoor fan work normally Replace the control panel AP1 End Normal protection please operate it after the outdoor ambient temp is normalized Improve the heat...

Страница 29: ...the fault is eliminated Replace the compressor End Check if the fan terminal OFAN is connected correctly Replace the capacitor C1 Remove foreign objects clean heat exchanger and increase ventilation...

Страница 30: ...ce it as per the wiring diagram and reconnect the wires If the fault is eliminated Remove the PFC capacitor and measure resistance between the two terminals Is the resistance around zero Disconnect th...

Страница 31: ...y before the failure occurs Check the wiring of the indoor and outdoor units with reference to the wiring diagrams Are wires broken Check the communication circuit of the outdoor unit The communicatio...

Страница 32: ...5 63 460 34 10 200 73 2 358 112 0 717 4 60 230 35 9 779 74 2 280 113 0 697 3 57 180 36 9 382 75 2 206 114 0 678 2 54 310 37 9 003 76 2 133 115 0 660 1 51 590 38 8 642 77 2 064 116 0 642 0 49 020 39 8...

Страница 33: ...310 35 13 040 74 3 040 113 0 930 3 76 240 36 12 510 75 2 940 114 0 904 2 72 410 37 12 000 76 2 844 115 0 880 1 68 790 38 11 520 77 2 752 116 0 856 0 65 370 39 11 060 78 2 663 117 0 833 1 62 130 40 10...

Страница 34: ...10 63 10 930 102 3 129 14 342 800 25 49 190 64 10 540 103 3 040 13 323 900 26 47 080 65 10 180 104 2 955 12 306 200 27 45 070 66 9 827 105 2 872 11 289 600 28 43 160 67 9 489 106 2 792 10 274 000 29 4...

Страница 35: ......