background image

8

TOOL AIR FITTINGS:

This tool uses a 1/4

 N.P.T. male plug. The inside diameter should 

be .28

 (7 mm) or larger. The fitting must be capable of discharging 

tool air pressure when disconnected from the air supply.

RECOMMENDED OPERATING PRESSURE:

70 to 100 p.s.i. (5 to 7 bar). Select the operating air pressure with-
in this range for best fastener performance.

DO NOT EXCEED 120 p.s.i. (8 bar).

4.

TECHNICAL DATA

1

NOISE

A-weighted single-event sound power level

------ LWA, 1s, d 97.44 dB

A-weighted single-event emission sound pressure level at 
work station

------ LpA, 1s, d 86.64 dB

These values are determined and documented in accord-
ance to EN12549 : 1999.

2

VIBRATION
Vibration characteristic value = 3.8 m/s

2

These values are determined and documented in accord-
ance to ISO 8662-11.
This value is a tool-related characteristic value and does not 
represent the influence to the hand-arm-system when using 
the tool. An influence to the hand-arm-system when using 
the tool will for example depend on the gripping force, the 
contact pressure force, the working direction, the adjust-
ment of mains supply, the workpiece, the workpiece sup-
port.

5.

APPLICATIONS

General constuction works including siding, decking, panel 
sheathing

Crating

Making wooden pallets

4. AIR SUPPLY AND CONNEC-

TIONS

Read section titled “SAFETY INSTRUCTIONS”

DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COM-
PRESSOR

The tool is designed to operate on compressed air. Do not oper-
ate the tool on any other highpressure gas, combustible gases 
(e.g., oxygen, acetylene, etc.) since there is the danger of an ex-
plosion. For this reason, absolutely do not use anything other 
than an air compressor to operate the tool.

OPERATE WITHIN THE PROPER AIR PRESSURE RANGE

The tool designed to operate within an air pressure range of 70 
to 100 p.s.i. (5 to 7 bar).
The pressure should be adjusted to the type of the work being 
fastened. The tool shall never be operated when the operating 
pressure exceeds 120 p.s.i. (8 bar).

DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUB-
STANCE

Never operate the tool near a flammable substance (e.g., thinner, 
gasoline, etc.). Volatile fumes from these substances could be 
drawn into the compressor and compressed together with the air 
and this could result in an explosion.

DO NOT USE A WRONG FITTINGS

The connector on the tool must not hold pressure when air supply 
is disconnected. If a wrong fitting is used, the tool can remain 
charged with air after disconnecting and thus will be able to drive 
a fastener even after the air line is disconnected, possibly caus-
ing injury.

WARNING

Thinner

Gasoline

Содержание TA551B/16-11

Страница 1: ...RUCTIONS WITH THE TOOL FOR FUTURE REFERENCE AVANT D UTILISER CET OUTIL LIRE CE MANUEL ET LES CONSIGNES DE SÉCURITÉ AFIN DE GARANTIR UN FONCTIONNEMENT SÛR CONSERVER CE MANUEL EN LIEU SÛR AVEC L OUTIL AFIN DE POUVOIR LE CONSULTER UL TÉRIEUREMENT ANTES DE UTILIZAR ESTA HERRAMIENTA LEA DETENIDAMENTE ESTE MANUAL PARA FAMILIARIZARSE CON LAS ADVERTENCIAS E INSTRUCCIONES DE SEGURIDAD CONSERVE ESTAS INSTRU...

Страница 2: ... une situation éventuellement dangereuse qui si elle n est pas contournée pourrait provoquer la mort ou des blessure sérieuses ATTENTION Indique une situation éventuellement dangereuse qui si elle n est pas contournée pourrait provoquer des blessures légères à moyennement sérieuses REMARQUE Souligne des informations importantes DEFINICIÓN DE LAS INDICACIONES DE ADVERTENCIA ADVERTENCIA Indica una s...

Страница 3: ...C of 21 DEC 1989 and provide both frontal and side protection The employer is responsible to enforce the use of eye pro tection equipment by the tool operator and all other person nel in the work area NOTE Non side shielded spectacles and face shields alone do not provide adequate protection 2 EAR PROTECTION MAY BE REQUIRED IN SOME ENVI RONMENTS As the working condition may include exposure to hig...

Страница 4: ...om these substanc es could be drawn into the compressor and compressed to gether with the air and this could result in an explosion 4 NEVER USE THE TOOL IN AN EXPLOSIVE ATMOS PHERE Sparks from the tool may ignite atmospheric gases dust or other combustible materials 5 DO NOT USE A WRONG FITTINGS The connector on the tool must not hold pressure when air supply is disconnected If a wrong fitting is ...

Страница 5: ...hould the tool be handled carelessly or when connecting the air fitting For this reason always remove all fasteners remaining in the magazine after completion of the operation 15 CHECK OPERATION OF THE CONTACT TRIP MECHA NISM FREQUENTLY IN CASE OF USING A CONTACT TRIP TYPE TOOL Do not use the tool if the trip is not working correctly as ac cidental driving of a fastener may result Do not interfere...

Страница 6: ...ays carry the tool by the handle never carry the tool by the air hose The tool must be used only for the purpose it was designed Never remove tamper with the operating controls e g TRIGGER CONTACT ARM Keep the tool in a dry place out of reach of chil dren when not in use Do not use the tool without Safety Warning label Do not modify the tool from original design or function without approval by MAX...

Страница 7: ...ook c Swivel Joint PRODUCT NO TA551B 16 11 HEIGHT 11 3 8 288 5 mm WIDTH 3 1 4 84 mm LENGTH 14 356 mm WEIGHT 5 5 lbs 2 5 kg RECOMMENDED OPERATING PRESSURE 70 to 100 p s i 5 to 7 bar LOADING CAPACITY 157 Staples AIR CONSUMPTION 0 039 ft3 1 1 at 100 p s i 7 bar operating pressure PRODUCT NO TA551B 16 11 CROWN 7 16 11 mm LENGTH 1 to 2 25 to 51 mm WIDTH 0 062 1 57 mm THICKNESS 0 055 1 40 mm GAUGE 16 9 ...

Страница 8: ...g decking panel sheathing Crating Making wooden pallets 4 AIR SUPPLY AND CONNEC TIONS Read section titled SAFETY INSTRUCTIONS DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COM PRESSOR The tool is designed to operate on compressed air Do not oper ate the tool on any other highpressure gas combustible gases e g oxygen acetylene etc since there is the danger of an ex plosion For this reason absolutely do...

Страница 9: ...ect the air supply 3 Inspect screw tightness 4 Check operation of the contact arm trigger if moving smoothly 5 Connect the air supply 6 Check the air leakage The Tool must not have the air leakage 7 Hold the Tool with finger off the trigger then push the con tact arm against the work piece The tool must not oper ate 8 Hold the Tool with contact arm free from work piece and pull the trigger The Too...

Страница 10: ...low rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally al lowed to recontact the work surface with the trigger still actuated finger still holding trigger pulled an unwanted second fastener will be driven CONTACT TRIP Identified by BLACK TR...

Страница 11: ...connect air supply before making adjustment The driving depth adjustment is made by adjusting the contact arm B 1 With air pressure set drive a few staples into a representa tive material sample to determine if adjustment is neces sary 2 If adjustment is required disconnect air supply 3 Take off hex bar wrench set in the magazine The screw M5 6 is loosened to allow the contact arm B to be moved up...

Страница 12: ...ES ALWAYS disconnect air supply before clearing jammed fastener 1 Take out the staples from the inside of the magazine 2 Release the staple removal lever and open the door 3 Remove staples that are jammed inside the nose by using a punch or slotted screw driver 4 After removing the staples Close the door and the staple removal lever Trigger Trigger lock dial WARNING Staple removal lever ...

Страница 13: ...t oiler Recommended Oil ISO VG32 5 INSPECT AND MAINTAIN DAILY OR BEFORE OPERA TION Disconnect air supply and empty the magazine when inspect ing or maintaining the tool 1 Drain air line filter and compressor 2 Keep lubricator filled in air 3 pieces set 3 Clean filter element of air 3 pieces set 4 Tighten all screws 5 Keep contact arm moving smoothly 7 STORAGE 1 When not in use for an extended peri...