8
TOOL AIR FITTINGS:
This tool uses a 1/4
″
N.P.T. male plug. The inside diameter should
be .28
″
(7 mm) or larger. The fitting must be capable of discharging
tool air pressure when disconnected from the air supply.
RECOMMENDED OPERATING PRESSURE:
70 to 100 p.s.i. (5 to 7 bar). Select the operating air pressure with-
in this range for best fastener performance.
DO NOT EXCEED 120 p.s.i. (8 bar).
4.
TECHNICAL DATA
1
NOISE
A-weighted single-event sound power level
------ LWA, 1s, d 97.44 dB
A-weighted single-event emission sound pressure level at
work station
------ LpA, 1s, d 86.64 dB
These values are determined and documented in accord-
ance to EN12549 : 1999.
2
VIBRATION
Vibration characteristic value = 3.8 m/s
2
These values are determined and documented in accord-
ance to ISO 8662-11.
This value is a tool-related characteristic value and does not
represent the influence to the hand-arm-system when using
the tool. An influence to the hand-arm-system when using
the tool will for example depend on the gripping force, the
contact pressure force, the working direction, the adjust-
ment of mains supply, the workpiece, the workpiece sup-
port.
5.
APPLICATIONS
General constuction works including siding, decking, panel
sheathing
Crating
Making wooden pallets
4. AIR SUPPLY AND CONNEC-
TIONS
Read section titled “SAFETY INSTRUCTIONS”
DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COM-
PRESSOR
The tool is designed to operate on compressed air. Do not oper-
ate the tool on any other highpressure gas, combustible gases
(e.g., oxygen, acetylene, etc.) since there is the danger of an ex-
plosion. For this reason, absolutely do not use anything other
than an air compressor to operate the tool.
OPERATE WITHIN THE PROPER AIR PRESSURE RANGE
The tool designed to operate within an air pressure range of 70
to 100 p.s.i. (5 to 7 bar).
The pressure should be adjusted to the type of the work being
fastened. The tool shall never be operated when the operating
pressure exceeds 120 p.s.i. (8 bar).
DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUB-
STANCE
Never operate the tool near a flammable substance (e.g., thinner,
gasoline, etc.). Volatile fumes from these substances could be
drawn into the compressor and compressed together with the air
and this could result in an explosion.
DO NOT USE A WRONG FITTINGS
The connector on the tool must not hold pressure when air supply
is disconnected. If a wrong fitting is used, the tool can remain
charged with air after disconnecting and thus will be able to drive
a fastener even after the air line is disconnected, possibly caus-
ing injury.
WARNING
Thinner
Gasoline