DISCONNECT THE AIR SUPPLY AND EMPTY THE MAGAZINE 
WHEN THE TOOL IS NOT IN USE

Always disconnect the air supply from the tool and empty the 
magazine when operation has been completed or suspended, 
when unattended, moving to a different work area, adjusting, dis-
assembling, or repairing the tool, and when clearing a jammed 
fastener.

FITTINGS:

 Install a male plug on the tool which is free flowing 

and which will release air pressure from the tool when discon-
nected from the supply source.

HOSES:

 Hose has a min. ID of  1/4" (6 mm) and max. length of 

no more than 17" (5 meters).
The supply hose should contain a fitting that will provide "quick 
disconnecting" from the male plug on the tool.

SUPPLY SOURCE:

 Use only clean regulated compressed air as 

a power source for the tool.

3-PIECE AIRSET

 (Air filter, Regulator, Oiler):

Refer to TOOL SPECIFICATIONS for setting the correct operat-
ing pressure for the tool.

NOTE:

A filter will help to get the best performance and minimum wear 
from the tool because dirt and water in the air supply are major 
causes of wear in the tool.
Frequent, but not excessive, lubrication is required for the best 
performance. Oil added thru the air line connection will lubricate 
the internal parts.

5. INSTRUCTIONS FOR OPERA-

TION

Read section titled "SAFETY INSTRUCTIONS".

1.

BEFORE OPERATION

Check the following prior operation.

1

Wear Safety Glasses or Goggles.

2

Do not connect the air supply.

3

Inspect screw tightness.

4

Check operation of the contact arm & trigger if moving 
smoothly.

5

Connect the air supply.

6

Check the air-leakage. (The Tool must not have the air-
leakage.)

7

Hold the Tool with finger-off the trigger, then push the con-
tact arm against the work-piece. (The tool must not oper-
ate.)

8

Hold the Tool with contact arm free from work-piece and pull 
the trigger. (The Tool must not operate.)

9

Disconnect the air supply.

2.

OPERATION

Wear safety glasses or goggles danger to the eyes always exists 
due to the possibility of dust being blown up by the exhausted air 
or of a fastener flying up due to the improper handling of the tool. 
For these reasons, safety glasses or goggles shall always be 
worn when operating the tool.
The employer and/or user must ensure that proper eye protection 
is worn. Eye protection equipment must conform to the require-
ments of the American National Standards Institute, ANSI Z87.1 
(Council Directive 89/686/EEC of 21 DEC. 1989) and provide 
both frontal and side protection.
The employer is responsible to enforce the use of eye protection 
equipment by the tool operator and all other personnel in the work 
area.

NOTE:

 Non-side shielded spectacles and face shields alone do 

not provide adequate protection.

Keep hands and body away from the discharge outlet when driv-
ing the fasteners because of dangerous of hitting the hands or 
body by mistake.

[AIR SUPPLY & CONNECTIONS]

Air filter

Air hose

Regulator

3-piece airset

Used at 70 to 100 p.s.i. (5 to 7 bar)

Air compressor

Oiler

WARNING

WARNING

Содержание SuperRoofer CN445R3

Страница 1: ...STRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE AVANT D UTILISER CET OUTIL LIRE CE MANUEL ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL E...

Страница 2: ...une situation ventuellement dangereuse qui si elle n est pas contourn e pourrait provoquer la mort ou des blessure s rieuses ATTENTION Indique une situation ventuellement dangereuse qui si elle n est...

Страница 3: ...1 DEC 1989 and provide both frontal and side protection The employer is responsible to enforce the use of eye pro tection equipment by the tool operator and all other person nel in the work area NOTE...

Страница 4: ...bar as the tool can burst 3 DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUBSTANCE Never operate the tool near a flammable substance e g thinner gasoline etc Volatile fumes from these substanc es could b...

Страница 5: ...G THE FASTENERS AFTER COMPLETING OPERATION If fasteners are left in the magazine after the completion of operation there is the danger of a serious accident occur ring prior to the resumption of opera...

Страница 6: ...ool Do not use the tool as a hammer Always carry the tool by the grip never carry the tool by the air hose The tool must be used only for the purpose it was designed Never remove tamper with the opera...

Страница 7: ...tool is designed to operate on compressed air Do not oper ate the tool on any other highpressure gas combustible gases e g oxygen acetylene etc since there is the danger of an ex plosion For this rea...

Страница 8: ...les 2 Do not connect the air supply 3 Inspect screw tightness 4 Check operation of the contact arm trigger if moving smoothly 5 Connect the air supply 6 Check the air leakage The Tool must not have th...

Страница 9: ...es If it does not engage check that the nail heads are in the slot on the Nose TEST OPERATION 1 Adjust the air pressure at 70 p s i 5 bar and connect the air supply 2 Without touching the Trigger depr...

Страница 10: ...be ignited by a spark causing an explosion Tar and dirt may build up on the Nose and Contact Arm This can prevent correct operation Remove any build up with kerosene 2 fuel oil or diesel fuel Do not...

Страница 11: ...ng else while the operator is holding the Trigger pulled SEQUENTIAL TRIP Identified by ORANGE TRIGGER CONTACT TRIP WITH ANTI DOUBLE FIRE MECHANISM Optional kit US patent 5597106 UK patent 2286790 The...

Страница 12: ...PERA TION Disconnect air supply and empty the Magazine when inspect ing or maintaining the tool 1 Drain air line filter and compressor 2 Keep lubricator filled in air 3 pieces set 3 Clean filter eleme...

Страница 13: ...e the quality of our products Les caract ristiques et la conception des produits mentionn s dans ce manuel sont sujettes des modifications sans pr avis en raison de nos efforts continus pour am liorer...

Отзывы: