4

Fi

le

 Na

m

e:

 M

ax

-A

ir_

IO

M

_ME

_G

03

5~

04

4_

LV

H

V_

M

od

_c

on

ve

rt

ed.

pdf

ME G 035~044 Series LV/HV | Mod

 

(con't)

  Installation, Operation and Maintenance Instructions

ME G035

ME G044

Supply

Torque Output (in-lb / Nm)

3540 in-lb / 400Nm

4430 in-lb / 500Nm

12V

Starting Current - DC Amps

22.0A

27.0A

Running Current - DC Amps

14.0A

14.9A

Speed (90°) @DC, seconds @ rated load

21 sec

29 sec

Motor, Voltage, Type, Class

12VDC 2-Pole Brush, Class F

12VDC 2-Pole Brush, Class F

Motor Power

80W

80W

Duty Cycle

100% (EN 60034) / Class A/B/C (ISO 22153)

24V

Starting Current - DC Amps

20.0A

20.0A

Running Current - DC Amps

7.7A

7.4A

Speed (90°) @DC, seconds @ rated load

21 sec

28 sec

Motor, Voltage, Type, Class

24VDC 2-Pole Brush, Class F

24VDC 2-Pole Brush, Class F

Motor Power

80W

80W

Duty Cycle

100% (EN 60034) / Class A/B/C (ISO 22153)

120V

Starting Current - AC Amps

7.0A

7.0A

Running Current - AC Amps

2.1A

2.0A

Speed (90°) @60Hz, seconds @ rated load

19 sec

26 sec

Motor, Voltage, Type, Class

120VAC Split-Phase Cap Run TENV Class F 120VAC Split-Phase Cap Run TENV Class F

Motor Power

80W

80W

Duty Cycle

100% (EN 60034) / Class A/B/C (ISO 22153)

230V

Starting Current - AC Amps

4.0A

4.0A

Running Current - AC Amps

1.1A

1.0A

Speed (90°) @60Hz, seconds @ rated load

20 sec

26 sec

Motor, Voltage, Type, Class

230VAC Split-Phase Cap Run TENV Class F 120VAC Split-Phase Cap Run TENV Class F

Motor Power

80W

80W

Duty Cycle

100% (EN 60034) / Class A/B/C (ISO 22153)

ALL

Environmental Rating

NEMA 4/4X & IP67

Electrical Entry

3/4'' EMT x 2

Control

Open/Close, Modulating, 2 Position, 3 Position

Auxiliary Switch - End of Travel

(2) Form C Volt-Free, Rated 10A @ 250vac, 5A @ 30VDC

Ambient Operating Range

-22°F~+149°F (-30°C~+65°C)

Humidity Range

0-95% RH

Altitude Limit

9850 ft / 3000 m

Weight (kg / lbs)

20 kg / 44.0 lbs

* All Amperage and speed specifications based on Open/Close Standard Duty motors @ 40°C ambient.

** Refer to 3 phase data sheets for 3 phase power.

Specifications

 

124

4.878 

 

275

10.821 

226

8.896

 

329

12.953 

 

40

1.575 

[341]

13.425

COVER REMOVAL CLEARANCE

[205]

8.070

 45° 

BCD  125 mm

  4.921 in

M12*1.75P

25mm DEPTH

4 POSITIONS

(ISO 5211 F12)

BCD  102 mm

  4.016 in

M10*1.5P

23mm DEPTH

4 POSITIONS

(ISO 5211 F10)

36mm DSQ

TS

 

108

4.243 

191

7.520

 

183

7.201 

3/4" NPT (2)

CONDUIT ENTRIES

 

124

4.878 

 

275

10.821 

226

8.896

 

329

12.953 

 

40

1.575 

[341]

13.425

COVER REMOVAL CLEARANCE

[205]

8.070

 45° 

BCD  125 mm

  4.921 in

M12*1.75P

25mm DEPTH

4 POSITIONS

(ISO 5211 F12)

BCD  102 mm

  4.016 in

M10*1.5P

23mm DEPTH

4 POSITIONS

(ISO 5211 F10)

36mm DSQ

TS

 

108

4.243 

191

7.520

 

183

7.201 

3/4" NPT (2)

CONDUIT ENTRIES

Dimensional Drawing