MT1020-340 (Rev B) 12/11
1
General Information
MT1020B Automated Tuner System Power Distribution Hub
The MT1020B Automated Tuner System Power Distribution Hub is designed to provide power and interface
control for the Maury USB series of automated mechanical tuners. As many as four units may be controlled
through this device. Connection to the host computer is made via a standard USB interface.
Specifications
USB Interface ................................... USB 1.1 and USB 2.0 compatible
Power Requirements........................ 100 to 264 VAC @ 47 to 63 Hz, 3 Amps
Mains supply voltage fluctuations not exceeding ±10% of the nominal
voltage. Transient over voltages according to over voltage category II
Output Power ................................... +5 VDC @ 5 Amps
+24 VDC @ 3.4 Amps
USB Power....................................... +5 VDC @ 500 mA per port
Environmental .................................. Indoor use only
Relative humidity, 90% non-condensing
Altitude up to 2000 meters
Pollution degree 2
Accessories Supplied
Qty Part
No.
Description
1
499-F-173-21
Spare fuse (5x20 mm, 3.1 A, slow-blow)
1
499-C-722
USB cable assembly
1
499-C-082
Power cord for 115 VAC (USA)
or 499-C-469
Power cord for 230 VAC (Europe, CE certified)
or
499-C-718 Power
cord
(China, CCC certified)