2/3/2020
Page 63 of 78
Calder Brothers Corporation
Model: M415XT Maintainer
M415XT
Computer Diagnostic
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
steering
modes
•
Coil damaged
Steering Mode 3
Coil Error
0x8062
•
coil disconnected/ damaged
•
Unable to
change
steering
modes
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible
at lower temperatures)
Invalid Pedal Data
0x8063
•
Pedal wiring issue
•
Drive
disabled
•
Check pedal
•
Damaged pedal
•
Replace pedal if necessary
•
Wiring harness fault
•
Check wiring
•
Pedal disconnected
eEP Logic Left
Param out of rng
0x8064
•
eEP parameters out of range
•
eEP disabled
•
check parameters in BODAS
service
•
pump goes
intp ET mode
eEP Logic Left Input
out of rng
0x8065
•
eEP inputs out of range
•
eEP disabled
•
check pump pressure sensors
•
pump goes
intp ET mode
•
check pump angle sensors
•
check wiring harness
eEP Logic Left
Tracking Lost
0x8066
•
difference between pump desired angle
and actual angle exceeds 15%
•
eEP disabled
•
check pump
•
pump damaged
•
pump goes
intp ET mode
•
check angle sensor
•
angle sensor damamged
•
check wiring harness
•
angle sensor disconnected
•
check connector to angle sensor
•
wiring harness issue
eEP Logic Right
Param out of
0x8067
•
eEP parameters out of range
•
eEP disabled
•
check parameters in BODAS
service
rng
•
pump goes
intp ET mode
eEP Logic Right
Input out of rng
0x8068
•
eEP inputs out of range
•
eEP disabled
•
check pump pressure sensors
•
pump goes
intp ET mode
•
check pump angle sensors
•
check wiring harness
eEP Logic Right
Tracking Lost
0x8069
•
difference between pump desired angle
and actual angle exceeds 15%
•
eEP disabled
•
check pump
•
pump damaged
•
pump goes
intp ET mode
•
check angle sensor
•
angle sensor damamged
•
check wiring harness
•
check connector to angle sensor
•
angle sensor disconnected
•
ensure sensors are connected to
correct sockets
•
wiring harness issue
•
ensure solenoids are connected
to
Содержание M415XT MAINTAINER