![Mauldin 650 2021 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/mauldin/650-2021/650-2021_operation-manual_1742300019.webp)
Page 19
650
Operations Manual Rev 1.1
Calder Brothers Corporation
Model:
650
Gravity Feed Paver
D.
Hydraulic System
Thoroughly review description of hydraulic system.
Use logical steps to determine cause of malfunction.
Identify the function or functions that require troubleshooting.
If possible, trace malfunction to source: pump, control, motor or cylinder.
Determine if pressure or volume is inadequate for function as specified:
Hydraulic System Pressures
Auxiliary circuits, gear pump
2800 p.s.i.
Main circuit, hydrostatic pumps
4350 p.s.i.
Hydraulic System Flows
Auxiliary circuits, gear pump
10 g.p.m.
Main circuit, hydrostatic pumps
13 g.p.m. each
(Flow determined at engine r.p.m. = 2900)
Problem
Possible
Cause
Correction
No Power or
Inadequate Power
Worn or Malfunctioning pump or
motor
Stuck relief valve cartridge.
Low system pressure caused by
worn pump.
Repair or replace pump or
motor
Repair or replace
Repair or replace pump
Surging of hydraulic items
Air in system due to low level of
oil, cavitating pump, leaky
fittings, pinched hose, etc.
Correct