DLC Installation

Instructions

Page 1

3/2/2012

BRISA 2000

With DOWNROD LIGHT CANOPY

READ AND SAVE THESE SAFETY AND INSTAllATION

INSTRUCTIONS.

Consult a licensed electrician

if unsure of any point below mentioned.

DANG ERIW ARNI NG/CAUTION

1.

High voltage and moving parts around motors and motor driven equipment can cause serious or fatal
injuries.

Always disconnect power source at main switch before wiring, servicing or cleaning unit. Do

not rely on fan control device to prevent unexpected start-up or electrical shock.

In addition, power

supply must have fuses or circuit breakers for short circuit protection.

2.

All electrical wiring must conform to national and local electrical codes such as: NEC, OSHA, etc.

3.

Fan should be secure in its electrical grounding to avoid possible electrical shock.

4.

Fan should not be used in any wet or hazardous

location defined

by article 500 of the NEC. In

addition, its ambient temperature should not exceed 104 degrees Fahrenheit.

5.

Power supply should conform to voltage rating of 115V.

6.

Before applying power, visually re-inspect the installation.

Make sure that all guards and protective

devices are securely in place and all visible screws and bolts are tightened.

7.

WARNING:

To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount To Outlet Box

Marked Acceptable for Fan Support

of

15.9

kg

(35

Ibs) or less

And Use Mounting Screws Provided

With The Outlet Box and/or Support Directly From Building Structure

8.

CAUTION: to reduce the risk of injury to persons, install fan so that bottom edges of fan blades are to

be: In Canada, to satisfy CSA requirements:

at least 8.3 Ft/2.5 M above the floor and all objects in

room if safety cages are utilized.

10.0 Ft if safety cages are not utilized.

In the US, to satisfy UL requirements:

at least 7.0 Ft above the floor and all objects in room if

safety cages are utilized.

10.0 Ft. if safety cages are not utilized.

9.

To reduce the risk of personal injury, do not bend blades or any other part of fan when cleaning.

Do

not insert foreign objects in between rotating fan blades or in space surrounding

entire rotating fan

unit. Fan must be turned off at power at supply source before installation, cleaning or servicing.

10. Instructions

for Supply Connections:

Conductor

of a fan identified

as grounded

conductor

to be

connected

to a grounded conductor

of a power supply, conductor

of fan identified as ungrounded

conductor to be connected to an ungrounded conductor of a power supply, conductor of fan identified
for equipment

grounding to be connected

to an equipment-grounding

conductor.

After making the

wire connections

in junction box, the splices should be turned upward and pushed carefully into the

outlet box.

The wires should be spread apart with the grounded conductor

and the fan-grounding

conductor

on one side of the junction

box and the ungrounded

conductor

on the other side of the

outlet box.

Be sure that all wiring connections

are properly insulated

from each other and any

surrounding

metal parts.

For safety and best operating

results, we recommend

that you have a

qualified electrician assemble and install your fan.

11. To reduce the risk of personal injury, install the supplementary

mounting

means and use only the

hardware provided with the fan.

12. WARNING:

TO REDUCE THE RISKS OF FIRE, ELECTRIC

SHOCK OR INJURY TO PERSONS,

OBSERVE

THE FOllOWING:

A.

Use this unit only in the manner intended by the manufacturer.

If you have any questions,

contact the manufacturer.

B. Before installing, servicing or cleaning unit, switch power off at service panel and lock service

panel to prevent power from being switched on accidentally.

13. WARNING:

To reduce the risk of fire, electrical shock or personal injury, mount to outlet box marked

acceptable for fan support and use screws provided with outlet box.

Содержание Brisa 2000

Страница 1: ...east 7 0 Ft above the floor and all objects in room if safety cages are utilized 10 0 Ft if safety cages are not utilized 9 To reduce the risk of personal injury do not bend blades or any other part o...

Страница 2: ...g bushing from top of central shaft A Insert narrow end of bushing into the shaft end of down_rod light canOpy support pole D with three holes iining up the twin mounting holes in both down_rod light...

Страница 3: ...bracket H which should have been already attached to your junction outlet box Oown rod light canopy support pole 0 is to be positioned in between the wings of bracket H Use larger bolt set L2 and aga...

Страница 4: ...HOOTING Contact Matthews Fan Company for assistance if your fan problem does not appear below Caution Turn off power at the service panel before servicing fan FAN VIBRATES DO NOT OPERATE FAN IF IT VIB...

Страница 5: ...guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and reg...

Страница 6: ...cket and the ball down rod fan assembly are firmly positioned The ball down rod assembly should not rotate any longer in the bracket if this is done properly The fan body itself should be free to rota...

Страница 7: ...21 Lbs Two canopies C1 and C2 C1 to cover junction box C2 to cover attachment of support pole D to fan body One support pole D one hanging bracket H and two bolt nut and lock washer sets L1 and L2 L2...

Страница 8: ...1 I 1 I I J 1 I i i I I j J Ii I q j I I I II 1 II I I I l i Safety Cage t t B Diagram II...

Страница 9: ...I I i I II I I i I 1 l Decorative Cage lA bC Diagram III...

Отзывы: