Matt:e SP-EVCP-R Скачать руководство пользователя страница 3

 

                     Single Phase 

EV Charger Protection unit 

 

 

 

                                                                

3 | 

P a g e

 

Once installed, the unit has a Live Mains Supply (230v or higher) 

within the enclosure. The cover must not be removed until the 

supply to the unit has been isolated or disconnected.

 

Product Description 

The

 matt

:

e

 Single Phase Electric Vehicle Charger Protection units (SP-EVCP-

T&R) are designed for use in domestic dwelling applications where single 

phase PME supplies are feeding Electric Vehicle Chargers. They should NOT 

be used on premises with 3 phase supplies 

 

This manual covers the SP-EVCP-T & SP-EVCP-R  

 

The units are not intended for any purpose other than that defined within 

this document. 

 

WARNINGS 

Please read and observe the following notices carefully. These warnings must 

be observed when installing and operating the Electric Vehicle Charger 

Protection units.

  

All relevant supplies must be isolated or disconnected before commencing any 

work.  This product must be installed by a competent person in accordance with 

the IEE Wiring Regulations, BS7671 (18

th

 Edition or later) and any relevant Building 

Regulations and/or Installation Regulations. 

 

Safety Advice 

The unit must be installed in a dry ventilated location; it must never be covered or 
have restricted ventilation. 

The SP-EVCP-R and SP-EVCP-T units are rated for a maximum 32A.  

 

For any information not contained within this document, please contact our 
technical support team on 01543 227290 or [email protected]

 

 

Содержание SP-EVCP-R

Страница 1: ...Electric Vehicle Charger Protection Units SP EVCP T SP EVCP R Installation Manual V1 0 Oct 2019...

Страница 2: ...ections 6 Operating Instructions 8 Specifications 9 Warranty 9 Declaration of Conformity 10 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiri...

Страница 3: ...at defined within this document WARNINGS Please read and observe the following notices carefully These warnings must be observed when installing and operating the Electric Vehicle Charger Protection u...

Страница 4: ...the incoming supply including CPC The isolation contactor is certified to BSEN 60947 and complies with the requirements of BS 7671 18th Edition The matt e SP EVCP technology does not require earth ro...

Страница 5: ...Single Phase EV Charger Protection unit 5 P a g e Please refer to the diagram below for the dimensions and mounting arrangements of the unit...

Страница 6: ...Single Phase EV Charger Protection unit 6 P a g e Electrical Connections The user wiring connections are indicated in the diagrams below...

Страница 7: ...Phase EV Charger Protection unit 7 P a g e Connect the incoming cable from the distribution board directly to either the terminals T version or the RCBO R version Connect the outgoing cable to the con...

Страница 8: ...ply switched on the unit will monitor the incoming supply voltage If the incoming supply is within limits approximately 5 seconds after switching on the contactor will energise and connect the load to...

Страница 9: ...X Document Revision V1 0 Oct 2019 Terminal Capacities Min Max Torque Incoming Terminals cable size tightening torque 0 5 mm 2 6 0mm 2 1 3Nm Incoming RCBO cable size tightening torque 2 5 mm 2 16 0mm 2...

Страница 10: ...Object of the declaration Electric Vehicle Charger Protection units SP EVCP T SP EVCP R The object of the declaration described above is in conformity with the relevant Union harmonisation legislatio...

Отзывы: