- 4 -
3. Outline (rough drawing)
##
4. Mounting
This product is designed for wall-mounting or setting on floor.
If mounting on wall, tighten with M6 screws at four mounting holes previously provided.
If setting on floor, place it on the flat floor.
* Resins (Plastics) attached on the case cover are protective layers during transportation for
securing the sponge packing. Please remove these when use the product, because these are
unnecessary.
Caution: Under any measuring environment and conditions outside the scope of specifications,
some malfunction may occur.
Important: If this product is exposed to heavy rainfall exceeding 30 mm, the indicated value
may change due to false detection of rain.
If you are concerned about false detection due to rain when using it outdoors, install
a roof to prevent this product from being exposed to rain.
*1) Make sure to connect the earth terminal.
*2) Make sure to tighten the lead outlet to prevent the outer air into Case.
For other connections like a conduit instead of our lead outlet plug, make sure to prevent
outer air from coming into the body by using putty etc. on the inlet lead wiring.
*3) Do not touch the probe directly by hand without grounding while power is ON.
Fig.1 Outline
!
!