3 Normal Operation
3-5
3-4-2 Setting Current, Voltage and OVP(No.2)
Out of the current, voltage and OVP settings, the desired one is set in the remote mode.
TTL LOW = (Voltage, Current or OVP) setting: remote mode
TTL HIGH = (Voltage, Current or OVP) setting: local mode
Or
External relay CLOSED = (Voltage, Current or OVP) setting: remote mode
External relay OPEN = (Voltage, Current or OVP) setting: local mode
①
Voltage set in the remote mode.
②
Current set in the remote mode.
TB1
TTL signal
10
22
21
-
+
External relay
5kΩ
100Ω
9
8
-S
(Common)
-S
(Common)
Power supply unit
Internal circuit
Remote mode.
User connection
TB1
TTL signal
10
-
+
External relay
5kΩ
100Ω
9
-S
(Common)
-S
(Common)
Power supply unit
Internal circuit
User connection