11. Troubleshooting 

 
If you think a failure has occurred, first turn off the unit and disconnect the input power. Make sure that no voltage is on the 
input/output terminals, and then check the input/output wiring. 
 
They are not always a failure in the following cases, check the unit once again before requesting our services. 

 

Problem 

 

Items to check 

”None of output” 

”The output does not meet the 

preset value." 

☐ 

☐ 

☐ 

☐ 

☐ 

☐ 

☐ 

Is the input voltage within the specifications? Is the wiring correct? 

Is the LS pin in the remote connector (TB1) on the rear panel short-circuited?   

Is the LD pin in the remote connector (TB1) on the rear panel short-circuited? 

Is the voltage setting minimized?

 

Are settings for Ilimit, OCP, and OPP minimized? 

Is the OVP setting correct? 

Is the LOCK function activated?

 

"Breaker trips" 

☐ 

 

☐ 

☐ 

Have you replaced the original screws of the housing with different ones? 

(The replaced screws may have cut into the internal circuits.) 

Is the breaker's base capacity sufficient? 

Are the inputs and outputs connected incorrectly? 

Output voltage fluctuates or 

cannot be controlled. 

☐ 

☐ 

Is the Ilimit operation set? 

Doesn't the peak current exceed its rated value? 

"Output current does not meet 

the desired one." 

"A protection becomes active 

when the connected load is 

activated." 

☐ 

☐ 

☐ 

☐ 

Is the RANGE setting correct? 

Doesn't the peak current exceed its rated value? 

Is the Ilimit setting value lower? 

Doesn't the inrush current exceed its rated value? 

 
 

Revision History 

 

Rev. No. 

Revised date 

Revised contents 

0.0 

2020/08/13 

First edition 

 

 

 

 
 
 

 

 

Содержание DRK4k Series

Страница 1: ... unavailable please contact our sales representatives Keep the manual with you so that you can read it whenever you want https www matsusada com product Table of Contents 1 Introduction 1 2 Accessories 1 3 For Safe Use 2 4 Initial Inspection 5 5 Simple operation from turning on the unit to outputting from the unit 5 6 Main and Protection Functions 5 7 External View 5 7 1 Connecting the cable for p...

Страница 2: ...der the supervision of those who are familiar with the proper use and danger of the product Persons with the exception of the above must not handle the product Do not open the product case and panel Do not disassemble remodel or repair by opening the product case and panel yourself There is a high voltage area inside which may possibly cause electric shock and fire Never remove the case and panel ...

Страница 3: ... the product in order to reduce the risk of current flowing through important organs of the body Keep your left hand off from the product and operate with your right hand Do not touch the wiring or load connected to the output terminal or output terminal during operation or immediately after output stop Very high voltage is applied to the terminals during normal operation and trial operation Touch...

Страница 4: ...e lifetime of fan varies greatly depending on the environment where it is used temperature humidity dust etc In order to use the product for a longer time it is necessary to replace the fan periodically For replacement please contact our sales office replacement require separate repair charges The replacement will require a separate repair fee There is a risk of electric shock do not replace it by...

Страница 5: ... terminal block can be used The rating of the front outlet is 250V 15A Make sure that the output has already been turned off with the OUTPUT switch OUTPUT LED Off Press the PROTECT switch and then turn the numerical value setting encoder It is set to the maximum at the factory shipment Press VLT switch and FRQ switch and then turn the numerical value setting encoder to set your desired voltage and...

Страница 6: ...dition The overload condition is determined by the settings of OCP and OPP 1 Press and hold the DISP key 2 After shifting to the Configuration screen turn the numeric value setting encoder clockwise to set the value to Cut off 9 LOCK Function Function Description Setting Key lock Lock all operations except for the OUTPUT switch and ENT LOCK key Press and hold the ENT LOCK key until the LK appears ...

Страница 7: ...etting minimized Are settings for Ilimit OCP and OPP minimized Is the OVP setting correct Is the LOCK function activated Breaker trips Have you replaced the original screws of the housing with different ones The replaced screws may have cut into the internal circuits Is the breaker s base capacity sufficient Are the inputs and outputs connected incorrectly Output voltage fluctuates or cannot be co...

Страница 8: ...8 ...

Отзывы: