6. Main Functions
・
Four-quadrant operation
・
Waveform generation function
・
Protection function
・
Memory function
・
Sequence function
・
Remote control function
7. Operation Procedure from POWER ON to
OUTPUT
8. Four-quadrant Operation
(7) Starting output
(1) Connection and start-up
Connect AC input cable to the rear panel connector.
Turn on the POWER switch on the front panel. Make
sure that the voltage/current setting screen appears on
the display.
(2) Setting operating mode
Select the CV/CC operating mode using CV/CC switch.
(3) Setting voltage and current
Select AC/DC setting values using the VOLT switch.
Set the voltage and current using the rotary encoder.
(4) Setting waveform
Select the type of waveform using the WAVE switch.
Select each setting option using the FREQ switch.
Change each setting value using the rotary encoder.
(5) Setting protection function
Call up the protection setting screen using the PROT
switch.
Select each protection setting option using VOLT switch.
Change each setting value using the rotary encoder.
(6) Setting monitoring display
Call up the measurement setting screen using the PROT
switch.
Select each setting option using the VOLT switch.
Change each setting value using the rotary encoder.
Turn ON/OFF the output using the OUTPUT switch.
It is possible to pass and sink
electric current in the range given
shown on the left.
AC operation range
DC operation range
Vo max: Rated output voltage
Io max:
Rated output current
Voltage/current setting screen
OFF: Output OFF
ON: Output ON