background image

5

1. DC Battery Input

Once correctly installed the MA21DCS needs the battery chemistry to be selected, then it will 

operate automatically with no further input.

  Start the vehicle and let it idle
  The charger will recognise that there is charge going into the main starting battery
   Once the main starting battery reaches 13.0V (11.5V if ignition sensor is installed), the MA21DCS 

will begin charging the auxiliary battery

   Change the battery chemistry setting to suit your application. The default setting is Lead Acid. 

Once selected, the charger will remember this as the new default setting, you do not need to 

change the setting again

   The charger will continue to operate until the vehicle is switched off (Ignition sensor connected) 

and/or the main starting battery drops to 12.4V

2. Solar Input

If a solar panel input is connected to the MA21DCS, it will automatically accept power from the 

panels once the engine has stopped running and the main battery has dropped to 12.4V.
Minimum solar input voltage is 13.5V, maximum is 25V. No regulator is required between the 

charger and the panels if the panel output voltage is within those parameters.

OPERATING THE CHARGER

Red LED indicates 

Solar input is active

The battery chemistry selected 

is indicated by the blue LED

Red LED indicates 

 POWER  in on

Red LED indicates 

the unit is CHARGING

GREEN LED indicates 

battery  is FULLY CHARGED

Charger Display

Содержание MA21DCS

Страница 1: ...batteries Gel Calcium and LiON LiFePO4 Internal charger temperature monitoring and power output control LED indicators showing stage of charge Over charging short circuit and over temperature protect...

Страница 2: ...ducted in a well ventilated area Inadequate ventilation may over heat the charger and cause inefficient operation The ACID FLUID within a battery is highly corrosive and poisonous It can produce flamm...

Страница 3: ...and connectors will be required to connect these to your vehicle panels etc if they are not already fitted Any existing or additional cables used in the installation of this product needs to be suitab...

Страница 4: ...le for this application Ensure ALL cabling meets specification and will not be exposed to excessive heat moving parts or abrasion Connect the auxiliary battery to the charger make sure polarity are co...

Страница 5: ...need to change the setting again The charger will continue to operate until the vehicle is switched off Ignition sensor connected and or the main starting battery drops to 12 4V 2 Solar Input If a so...

Страница 6: ...3 LiFePO 14 4 Float Charge Voltage V DC 13 5 Float Charge Current mA 100 Suits battery capacity AH 18 250 Case Construction Aluminium Ingress protection IP rating IP65 Max operating temp Deg C 70 Weig...

Страница 7: ...normal life expectancy Your average compressor style fridge uses up to 5 amps Over a 24 hour period it should use approximately 30 amp hours Therefore if the 100AH battery is operating only the fridge...

Страница 8: ...the purpose for which it was intended You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Trid...

Отзывы: