63
8.2 mCb led INSTrUCTIoNS
led
refereNCe deSIGNaTor deSCrIPTIoN
RS485
DSP2
Indicates if the digital communication is working normally between the console and the MCB.
Blinking = Normal.
Off = Fault
MCU
DSP1
Indicates if the console is working normally.
Blinking - Normal.
Light = MCU Fault.
Off = MCU No Power.
DOWN
DSP5
Indicates if the console is commanding elevation down.
Light = Normal.
Off - No command from console received by the elevation motor.
UP
DSP6
Indicates if the console is commanding elevation up.
Light = Normal.
Off = No command from console received by the elevation motor.
+12V
DSP4
Indicates if the console voltage supply is present.
Light = Normal.
Off - 12 Volts are not provided by the MCB.
CHaPTer 8: TroUbleSHooTING
Содержание T7XI-01
Страница 1: ...T 7 x I 0 1 T r e a d m i l l S ER V I C E MA N U A l ...
Страница 4: ...1 1 1 Serial Number Location Chapter 1 Serial number Location ...
Страница 62: ...59 8 1 Electrical DiagramS Chapter 8 Troubleshooting ...
Страница 64: ...61 8 1 Electrical Diagrams CONTINUED UCB Little Board Wire Chapter 8 Troubleshooting Hand Pulse Wire ...
Страница 65: ...62 8 1 Electrical DiagramS CONTINUED Chapter 8 Troubleshooting Quick key connect wire ...
Страница 136: ...133 NOTES ...