36
ERROR MESSAGE 02A0 / 02A8
1) CAUSE:
a. 02A0 - Main motor failure. The belt does not move when it is supposed to move.
b. 02A8 - Inverter circuit of the motor failed. Motor resistance is closed.
2) SOLUTION:
a. Check the connection of the motor cable at the MCB (Figure A).
b. Use a multi - meter to check the motor cable for resistance at 3 points (Figures B, C, & D).
c. If the motor cable displays an ohm value, replace the MCB.
d. If the motor cable does not display an ohm value, replace the motor.