![Matrix r7xi-02 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/matrix/r7xi-02/r7xi-02_service-manual_1740466068.webp)
65
CHAPTEr 8: TroUBlESHooTiNg
8.5 TroUBlESHooTiNg - Error 04B0
figUrE A
figUrE B
Error CoDE 04B0
1) SyMPToM:
04B0 – LCB communication disconnected.
2) SolUTioN:
1) If the display is giving a 04B0 error, check the LCB LED10 status.
- LED10 blinking: Turn off power and after 3 seconds, turn on power again. If the console shows the 04A0 error, skip to Step 2.
- LED10 off: Check the connection of the digital communication wire at the UCB and LCB (Figure A & B). If the connection is good, replace
the digital communication wire.
2) If LEDs 7 / 8 / 9 / 10 blinking together, this should be LCB software problem. Re-install LCB software. If this does not resolve the issue,
replace the LCB.
Содержание r7xi-02
Страница 1: ...r 7 x i 0 2 B I K E S E R V I C E M A N U A l...
Страница 4: ...1 1 1 Serial Number Location Chapter 1 Serial Number Location fRAME Serial number location...
Страница 61: ...58 8 1 Electrical Diagrams Chapter 8 Troubleshooting...
Страница 62: ...59 chapter 8 Troubleshooting 8 1 Electrical Diagrams CONTINUED...
Страница 63: ...60 8 1 electrical diagramS CONTINUED Chapter 8 Troubleshooting MCB POWER Wire Digital Communication Wire...
Страница 64: ...61 8 1 electrical diagramS CONTINUED Chapter 8 Troubleshooting PULSE SENSOR WIRE...
Страница 66: ...63 8 3 uCB Wiring connections Chapter 8 Troubleshooting...
Страница 128: ...125 final assembly 10 2 assembly instructions continued chapter 10 Bike specifications and assembly guide...
Страница 165: ...162 notes...