MOTOR OVERLOADING troubleshooting
[Symptom Machine can’t start ]
Press start, when press incline up or down remove the incline motor
display show the “MOTOR OVERLOADING ”
“
[Cause]
Incline motor damaged.
[Solution]
1.
Open the incline motor left and right side cove. (Figure A)
2.
Press & Hold “LEVEL” both "
▲
and
▼
" at the same time for 3-5 sec.
Then, the dot vision display will show “MANAGER”
3.
Select the P11 incline calibration and press “START” key running it, when
the check the right or left incline motor remove is slow or not remove, this
incline is damage, please replace it.
Figure (B)
Figure (A)
Содержание MX-A5 Series
Страница 1: ...1 MX A5x SERVICE MANUAL...
Страница 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Страница 6: ...6 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Страница 7: ...7 MX A5x WIRING DIAGRAM INSTRUCTION...
Страница 8: ...8 P05 Digital cable console cable P04 Pulse sensor wire...
Страница 9: ...9 P02 Elevator Wire P14 ECB Load Wire...
Страница 10: ...10 SECTION 3 CONSOLE ENGINEERING MODE GUIDE...
Страница 12: ...12...
Страница 13: ...13 MANAGER SCREN DESCRIPTIONS...
Страница 14: ...14...
Страница 15: ...15 SECTION 4 LCB3 LED INSTRUCTIONS...
Страница 17: ...17 SECTION 5 TROUBLESHOOTINGS...
Страница 32: ...32 SECTION 6 Part Replacement Guide...
Страница 36: ...36 Step6 Put the incline motor tube on fixed stand Step5 Fix the incline motor...
Страница 38: ...38 SECTION 7 SOFTWARE UPGRADE PROCEDURE...
Страница 41: ...41 Install the MSP430 Tools Computer...
Страница 42: ...42 Press the Load Image Installation software to MSP430 Tools...
Страница 43: ...43 Installing the MSP430 cable to console MSP430...