18
Burner
LPG Injector
Natural Gas Injector
Semi-Rapid
65
97
Rapid
85
118
Wok
95
140
Natural Gas to LPG conversion
This appliance can be converted from natural gas to propane operation at a nominal inlet pressure of 37mbar, or butane
operation at a nominal inlet pressure of 28/30mbar. This conversion must only be carried out by a competent person (i.e.
a Gas Safe registered fitter).
Instructions to fit replacement hob injectors:
1. Disconnect the appliance from the gas and electrical supplies.
2. Remove burner components and pan supports.
3. Remove the injectors with a 7mm socket spanner and replace with the corresponding injectors as shown in the
table below.
4. Refit the burner components and pan supports.
5. Regulate the burner minimum flow rates (see page 19).
When converting from Natural Gas to LPG, it is important that the LPG identity sticker is placed on or adjacent to the
rating plate on the appliance.