INTENDED USE

The intended use of the Matrix MD-S711 Medical Leg Extension / Leg Curl is 

to create a predetermined, defined physical activity level for the patient. The 

physical activity level is generated by the user pushing against a movable leg 

bar. The user can either use the back of the ankle to press the leg bar in the 

downward direction to perform a Leg Curl exercise, or the user use the front of 

the shin to press the leg bar in the upward direction to perform a Leg Extension 

exercise. This physical activity level can be done in the controlled environment 

of a doctor’s office or a clinician’s lab. The stress intensity of the physical activity 

level can be adjusted by adjusting the amount of resistance applied to the leg bar, 

or by the perceived effort as described by the user to the doctor or clinician.

Metabolic System: The medical leg extension / leg curl can be 

used to influence the metabolic system to increase fat-burning, 

thereby reducing the size of adipose tissue deposits.

Physical Performance Tests: The defined stress intensity of the 

physical activity level can be used to perform physical performance 

tests on the strength of the user’s leg muscles. 

Recovery: Under a doctor’s care, the medical leg extension / leg 

curl can be used to improve muscle strength after surgery or injury. 

The handrails and seat of the medical leg extension / leg curl can 

be used for additional safety and stabilization of the patient.

Orthopedic Rehabilitation: Under a doctor’s care, the medical leg extension 

/ leg curl can be used for orthopedic rehabilitation (e.g. supporting 

defined/reduced weight to strengthen the legs of a user).

NOTE

1.  Ambient temperature for operating this equipment is 5°C - 40°C (with NO air-

flow), nominal 25°C.

2.  Relative Humidity for operating this equipment is 10% - 90% (non-condensing), 

nominal 40% (non-condensing).

3.  Ambient temperature for shipping and storage this equipment is from -20°C to 

70°C (with NO air-flow).

PROPER USAGE

1.  Do not exceed weight limits of the exercise device.
2.  If applicable, set safety stops to appropriate height.
3.  If applicable, adjust seat pads, leg pads, foot pads, range of motion 

adjustment, or any other type of adjustment mechanisms to a comfortable 

start position. Make certain that the adjusting mechanism is fully 

engaged to prevent unintentional movement and to avoid injury.

4.  Sit on bench (if applicable) and get into appropriate position for exercise.
5.  Exercise using no more weight than you can safely lift and control.
6.  In a controlled manner, perform exercise.
7.  Return weight to its fully-supported start position.

Содержание MD-S711

Страница 1: ...MD S711 MEDICAL LEG EXTENSION LEG CURL ...

Страница 2: ...2 ...

Страница 3: ... avoid injury INSTALLATION 1 STABLE AND LEVEL SURFACE MATRIX exercise equipment must be installed on a stable base and properly leveled 2 SECURING EQUIPMENT Manufacturer recommends that all stationary MATRIX strength equipment be secured to the floor to stabilize equipment and eliminate rocking or tipping over This must be performed by a licensed contractor 3 Under no circumstances should you slid...

Страница 4: ... s leg muscles Recovery Under a doctor s care the medical leg extension leg curl can be used to improve muscle strength after surgery or injury The handrails and seat of the medical leg extension leg curl can be used for additional safety and stabilization of the patient Orthopedic Rehabilitation Under a doctor s care the medical leg extension leg curl can be used for orthopedic rehabilitation e g...

Страница 5: ...e the pad to a comfortable start position 2 Back Pad Start Position Pull handle upward adjust the back pad to a comfortable start position release handle Allows the user to adjust the starting position of the back pad The user pulls the outermost handle upwards chooses comfortable start position and then releases handle 3 Seat Pivot Change Pull pin adjust the seat height to correct exercise start ...

Страница 6: ...tal weight pins and insert above head plate to achieve desired starting weight 6 Thigh Pad Rotation Pull pin rotate thigh pad out release pin Allows the user to swing the thigh pad out away from the user for easy entrance and exit of the machine 7 Thigh Pad Release Depress lever with thumb raise or lower pad release lever Allows the user to raise or lower the thigh pad into a comfortable start pos...

Страница 7: ...ECKLIST ACTION FREQUENCY Clean Upholstery 1 Daily Inspect Cables 2 Daily Clean Guide Rods Monthly Inspect Hardware Monthly Inspect Frame Bi Annually Clean Machine As Needed Clean Grips 1 As Needed Lubricate Guide Rods 3 As Needed 1 Upholstery Grips should be cleaned with a mild soap and water or a non ammonia based cleaner 2 Cables should be inspected for cracks or frays and immediately replaced i...

Страница 8: ...sembly confirm all the components by matching them with the exploded diagrams Carefully unpack the unit from this box and dispose of the packing materials in accordance with your local laws Exercise device must be assembled by a trained assembly team or be pre assembled prior to delivery CAUTION To avoid injury to yourself and prevent damage to the frame components be sure to have proper assistanc...

Страница 9: ...150L Nylock Nut M10 Bolt M10x105L Bolt M10x80L 2 7 2 12 2 8 2 2 2 A I Step 2 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 Do not fully tighten frame connectors until assembly is complete Vibra Tite 135 Red Gel or equivalent must be used on all fasteners that are not assembled with Nylock Nuts ENGLISH pre installed pre installed ...

Страница 10: ...B A A B D E D F J 3 4 Step 3 Hardware Description Qty J Set Screw ST4x20L 1 Step 4 Hardware Description Qty A B D E F Bolt M10x20L Washer Φ10 2 Arc Washer Φ10 5 Bolt M10x150L Nylock Nut M10 10 8 6 2 2 ENGLISH ...

Страница 11: ... Step 2 Hardware Description Qty A B K L M N Bolt M10x20L Washer Φ10 2 Bolt M8x15L Washer Φ8 5xΦ60 Axle Φ25 0x88 POM Washer 41 8xΦ20 5 1 1 1 1 1 2 ENGLISH Step 5 Hardware Description Qty A I Bolt M10x20L Washer Φ10 5xΦ42 1 1 ...

Страница 12: ...12 P A R Q O P O B 7 8 Step 7 Hardware Description Qty B O P Washer Φ10 2 Bolt M10x25L Plug 4 6 2 Step 8 Hardware Description Qty A P Q R Bolt M10x20L Plug Bolt M8x25L Washer Φ8 4 2 2 2 2 ENGLISH ...

Страница 13: ...Q R Step 10 Hardware Description Qty Q R Bolt M8x25L Washer Φ8 4 4 4 ENGLISH Step 9 Hardware Description Qty A I R S T Bolt M10x20L Washer Φ10 5xΦ42 Washer Φ8 4 Wavy Washer Φ30 5 Nylock Nut M8 1 1 1 1 1 ASSEMBLY COMPLETE ...

Страница 14: ...14 OPTIONAL ASSEMBLY SOLD SEPARATELY INCREMENTAL WEIGHTS D C B A STEP STOOL ENGLISH Hardware Description Qty A B C D Plug pre installed Bolt M10x20L Spring Washer Φ10 2 Arc Washer Φ10 2 2 2 2 2 ...

Страница 15: ......

Страница 16: ...MD S711 2019 Johnson Health Tech Part XXXXXXXXXX Rev 1 1 A ...

Отзывы: