22
high oR No ReSiSTANCe
PoSSiBle CAUSeS:
1) The console cable is damaged or not properly plugged in.
2) The UCB is damaged.
3) The Generator is damaged.
4) The LCB is damaged.
SolUTioN:
1) Check the console cable connections at the UCB and LCB.
2) Check if the generator is outputing variable power:
a. Insert the probes from a multi-meter into the black and red wires on the generator wire harness connector (Figure A).
b. When pedaling, the output voltage from the generator should vary depending on the RPM. The generator should output 120 VAC at 94
RPM.
3) If the generator does not have variable power, replace the generator.
4) If the generator does have variable power, replace the LCB.
figURe A
7.7 TRoUBleShooTiNg - ReSiSTANCe iSSUeS
ChAPTeR 7: TRoUBleShooTiNg
Содержание h5x-02
Страница 1: ...h 5 x 0 2 B i k e S E R V I C E M A N U A l...
Страница 2: ......
Страница 6: ...2 console serial number location 1 1 SERIAL NUMBER LOCATION CONTINUED Chapter 1 Serial number location...
Страница 18: ...14 Chapter 7 TROUBLESHOOTING 7 1 Electrical Diagrams...
Страница 19: ...15 7 1 Electrical Diagrams Chapter 7 Troubleshooting...
Страница 20: ...16 Chapter 7 TROUBLESHOOTING 7 1 Electrical Diagrams...
Страница 56: ...52 step 2 Chapter 9 bike SPECIFICATIONS AND ASSEMBLY GUIDE 9 3 ASSEMBLY INSTRUCTIONS CONTINUED...
Страница 57: ...53 9 3 Assembly Instructions Continued Chapter 9 bike SPECIFICATIONS AND ASSEMBLY GUIDE step 3...
Страница 58: ...54 step 4 Chapter 9 bike SPECIFICATIONS AND ASSEMBLY GUIDE 9 3 ASSEMBLY INSTRUCTIONS CONTINUED...
Страница 59: ...55 9 3 ASSEMBLY INSTRUCTIONS CONTINUED Chapter 9 bike specifications and assembly guide Step 5...
Страница 60: ...56 Step 6 9 3 assembly instructions continued Chapter 9 bike SPECIFICATIONS AND ASSEMBLY GUIDE...
Страница 63: ...59 NOTES...