Matrix COSEC ARGO Скачать руководство пользователя страница 4

 
 
 
 
 
 

 

Built In Cameras

 

• 

For providing efficient Face Recognition, two Cameras are used in 
COSEC ARGO.

 

 

• 

These Cameras are 2MP with Focal length of 2.8mm. The Cameras 
detect liveness and capture user images. The captured image is used 
to identify user for Time and Attendance Management.

 

 

What your Package Contains

 

• 

The Flush Mounting plate is available in the package. This plate will be 
required for Flush Mounting of COSEC ARGO. For details see 
Installation Instructions for Flush Mounting.

 

 

Wall Mounting: 

Select a location. It must be a flat surface such as wall, 

close to the access point (door).

 

 

Flush Mounting

: Select a wooden door or a location where the duct can 

be made. The rectangular duct has to be made in the wooden door in 
which Flush Mounting plate will be installed.

 

 

For 

Concealed wiring 

in Wall Mounting/Flush Mounting, first draw out

 

1)

 

COSEC ARGO Unit

 

2)

 

Flush Mounting Plate

 

3)

 

Wall Mounting Plate

 

4)

 

Four Screws M5/25

 

5)

 

Four Screw Grips

 

6)

 

Overswing  Diode

 

7)

 

Power Adapter 12VDC,2A

 

8)

 

Power Supply Cable (with DC Jack)

 

9)

 

EM Lock Cable

 

10)

 

External Reader Cable

 

11)

 

Flush Mounting Template

 

sufficient length of the cables from the hole of the mounting plate.

 

 

For 

Non-concealed wiring 

in Wall Mounting; the knock -out area has to 

be removed from outside by pressing on the bottom duct as shown 
in 

Figure 2

.

 

Preparation for Installation

 

Before Wall Mounting and Flush Mounting of COSEC ARGO follow below 
instructions.

 

 

• 

Remove the mounting screw from mounting screw hole at the bottom 
of device as shown in 

Figure 2

. The screw will be required to fix the 

device after Wall Mounting or Flush Mounting.

 

 

• 

Slide the back plate downwards to unlock the device from the 
mounting hook and then remove it by pulling it outwards. This back 
plate servers as the Wall Mounting plate. For details see Installation 
Instructions for Wall Mounting.

 

The connection of EM Lock must be done using the diode for Back 
EMF protection.

 

 

 

8

 

Содержание COSEC ARGO

Страница 1: ...servestherighttomakechangesinproduct designandspecificationswithoutpriornotice 29 InstallationInstruction WallMounting 9 InstallationInstruction FlushMounting 15 ConnectingtheCables 21 ConfiguringtheS...

Страница 2: ...ariants as follows 1 COSECARGOFACEE 2 COSEC ARGO FACEM 3 COSEC ARGO FACEI Figure 1 Front View Touch Screen Display RGB Camera IR Camera Figure2 BottomView IR LED Mounting Screw Hole Knock Out Area Fig...

Страница 3: ...130cm maximum as shown in Figure 6 4 Minimumrecommendeddistanceoftheuser sfacefromthecamera of the device is 30cm while maximum recommended is 120cm as shown in Figure 6 Figure 5 5 Do not install on u...

Страница 4: ...ECARGOUnit 2 FlushMountingPlate 3 Wall Mounting Plate 4 Four ScrewsM5 25 5 FourScrewGrips 6 Overswing Diode 7 PowerAdapter 12VDC 2A 8 PowerSupply Cable with DC Jack 9 EM Lock Cable 10 External ReaderC...

Страница 5: ...etracedmarkings FixWall Mountingplatewiththesuppliedscrews Tightenthescrewswitha screw driver 9 2 1 Installation Instruction Wall Mounting Step1 PlacetheWall Mountingplateand tracescrewholes1 and2onth...

Страница 6: ...he device in non concealed wiring KeepallthecablesparalleltothesideoftheCOSECARGO body in such a way that it should not cover the back portion oftheunitas illustratedinfigure below Radially curve all...

Страница 7: ...sertthemountingscrewintothemountingscrewhole atthebottomofthedevice Tightenthescrewtocompletethe Wall Mounting 13 Step4 AlignCOSECARGOonthemountingplateand hook itintothemountingslot Pressthebottomsid...

Страница 8: ...D C A B Flush Mounting Template B Figure8 Figure7 A InstallationInstruction FlushMounting Step1 PlacetheFlushMountingTemplateonthedesired installation surface Marktheareaalongthedottedlineandtracethef...

Страница 9: ...ll Figure 10 Mounting Slots Cable Connectors Mounting Screwhole KeepallthecablesparalleltothesideoftheCOSECARGO FACE body in such a way that it should not cover the back portion of the unit as illustr...

Страница 10: ...ntingscrewintothemountingscrewhole atthebottomofthedevice Tightenthescrewtocompletethe Flush Mounting 19 Figure 12 Step 4 Align COSEC ARGO with the Flush Mounting plate and hookitintothemountingslot P...

Страница 11: ...1 White 3 BEEPER Yellow 4 GREENLED Orange 5 GND Black 6 RS 232 RX Pink 7 12V RDR Red 8 RS232 TX Grey 1 GND Black 2 12VDCIN Red Power External Reader Figure 14 Connecting the Cables For Concealed wiri...

Страница 12: ...ic ConfiguringtheSettingsfromARGOFACE AssigningIP Server Address toDevice Forfirsttimeuseronly 23 GND Connect the Overswing diode in reverse biased condition paralleltotheEMLockforbetterlifetimecontac...

Страница 13: ...ons Figure24 TapSettings Figure23 TapAdmin 25 Ifyouarelogginginforthefirsttime youneedtosetthe PasswordinChooseNewPasswordandconfirmthe same in Confirm New Password Figure22 EnterPassword Figure21 Tap...

Страница 14: ...re31 TapAboutDevice Checking the Connectivity Status 27 Figure30 SettheServerConfigurations COSEC VYOM Figure 29 Select Server as VYOM IncaseofCOSECVYOM Figure28 SettheServerConfigurations COSEC CENTR...

Страница 15: ...age Open the Web Browser in your computer Enter the IP Address of the COSEC ARGO default http 192 168 50 1 in the address bar of the browser and press the Enter key on your computer keyboard TheLoginp...

Страница 16: ...For COSEC VYOM EntertheTenantID forexampleseeFigure37 ClicktheSubmitbutton theWebServerURL Address and Directory Name will be fetched automatically from the Server which cannot be modified see Figure...

Страница 17: ...tiveIPStouchscreen with Gorilla glass3 0 Resolution 480x320 pixels HVGA User Capacity 50 000 Communication Port Mobile Broadband Ethernet and WiFi Technical Specification Built In WiFi Yes IEEE 802 11...

Страница 18: ...e Warning Thisis aClass A product In a domestic environment this product may causeradiointerferenceinwhichcasetheusermayberequiredtotake adequate measures FCC Certificationin Progress Disposal Of Prod...

Страница 19: ...91 1800 258 7747 Email Support MatrixComSec com 37 Website www matrixaccesscontrol com FCC RF Radiation Exposure Statement 1 This Transmitter must not be co located or operating in conjunction with an...

Отзывы: