![Matrix Vision mvBlueGEMINI Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/matrix-vision/mvbluegemini/mvbluegemini_technical-manual_1741404030.webp)
mvBlueGEMINI Technical Manual (EN) v
1.2.2
APPENDIX
-
CONTROL
COMMANDS
29
Lenght in bytes
Structure
Value
Description
4
uint32
Day
4
uint32
Hour
4
uint32
Minute
4
uint32
Second
The camera may discard or convert invalid values.
To set date and time to 2016-06-25 10:11:12 send the following data (hex):
50535642
18000000
33000000
E0070000
06000000
19000000
0A000000
0B000000
0C000000
Set input data
Some inspections require input data which are compared with the acquired data of the smart
camera. These data can be sent to the smart camera using this message. The tool "
Receive data
"
interprets the input data.
Lenght in
bytes
Structure Value
Description
4
uint32
42565350
hex
Magic number
4
uint32
User data length in bytes
4
uint32
34
hex
Message ID
4
uint8[]
Input data for the inspection as specified in
mvIMPACT
Configuration Studio (mvIMPACT-CS)
.
Trigger inspection
Is sent to the smart camera to trigger an inspection.
Lenght in bytes
Structure
Value
Description
4
uint32
42565350
hex
Magic number
4
uint32
00
hex
User data length in bytes
4
uint32
40
hex
Message ID
Содержание mvBlueGEMINI
Страница 1: ...0 Version 1 2 2 Date 21 07 2016 mvBlueGEMINI Technical Manual EN...
Страница 4: ...mvBlueGEMINI Technical Manual EN v1 2 2 IMPRINT ADDRESS 3...
Страница 41: ...mvBlueGEMINI Technical Manual EN v1 2 2 APPENDIX NOTES ON NETWORK CONNECTIONS 40 Versions with OpenVPN bridge...
Страница 42: ...mvBlueGEMINI Technical Manual EN v1 2 2 APPENDIX NOTES ON NETWORK CONNECTIONS 41...