MSC-CP8X8E Product Manual
commands.
System parameter values can be set in Stored memory and/or Active memory. Stored values are loaded on
system startup. Active values are the current control values of the running system, but wont be retained after a
system restart if they differ from the Stored value.
Command
Arguments
Description
[Parameter]
Query Active parameter values.
[Parameter]
Query Stored parameter values.
[Parameter][Value]
Set Active/Stored parameter value (depends on parameter).
[Parameter][Value]
Set Active value of a parameter only.
[Parameter][Value]
Set Stored value of a parameter only.
Table 7: System Parameter Commands
Parameter identifiers are represented as one or more alphanumeric words separated by periods, representing a
tree structure similar to file folders or directories. Table 8 below describes the columns in the
Parameter
Parameter identifier consisting of one or more words separated by periods.
Value
section for details.
Access
Parameter access.
R
for Readable settings,
W
for writable settings, or
RW
for both.
Set
Default parameter memory used with the
A
for Active,
S
for Stored, or
AS
for
both. Commands which use only Stored memory require a reboot to become Active.
Table 8: System Parameter Table Columns
Page 19 of 55
© 2013-2018 Matrix Switch Corporation