Matrix Switch Corporation MSC-1HD1616L Скачать руководство пользователя страница 7

MSC-1HD1616L Product Manual

1 Getting Started

Congratulations on your purchase of a quality Matrix Switch Corporation product.  This section contains a 
general overview of device functionality and provides information to get you up and running quickly.  
Additional sections in this manual can be consulted for more detailed information on the subsystems and 
features of this product.

1.1 Device Connections

The 

MSC-1HD1616L

 comes with a power supply adapter, a redundant power supply (if ordered) and a 

documentation CD.  Additional cables and hardware are not usually provided.

Power supply adapter

 – A 12 Volt 3 Amp power supply adapter is provided which is connected to the 

5.5mm OD 2.1mm ID coaxial connector on the device and plugged into a 100-240V 50/60Hz AC power 
source.

Redundant power supply (Optional)

 – The additional redundant power supply can be connected via 

the second power supply connector (if applicable), to provide an additional power source in the event 
that one of the supplies fails or is disconnected from the power source.

Ethernet connector (Optional)

 – Connect to a network switch with an Ethernet cable.  Required for 

accessing the web page interface, TCP/IP Mascot interface or for interfacing with remote control panels. 
A crossover cable can also be utilized for connecting directly to a computer or remote panel.

SDI Video Inputs

 – Connect SDI sources to input connectors using 75 Ohm Coax cable with BNC 

connectors designed for high speed SDI video applications.  Unused inputs can be left unconnected. 
Inputs with supported standard rate (3G, HD or SD) SDI signals will be auto re-clocked for reduced 
jitter.  Other non standard rates between 125 Mbit/s and 2.97 Gbit/s will be passed through without re-
clocking or jitter reduction.  Adaptive cable equalization on each input can equalize input signals from 
Belden type 1694A cables up to lengths of 120m (@3G), 140m (@HD) and 400m (@SD).

SDI Video Outputs

 – Connect SDI destinations to output connectors using 75 Ohm Coax cable with 

BNC connectors designed for high speed SDI video applications. Unused outputs can be left 
unconnected.  Outputs utilize standard SMPTE levels of 800mV peak-to-peak.

External Audio Router (Optional)

 – An additional Matrix Switch Corporation AES or analog audio 

router can be utilized with this router by connecting it to the AFV connector with a 25 pin straight 
through cable, adding an additional audio level independent of SDI embedded audio.  

NOTE:

 The audio

router should be powered on before the video router to ensure proper initial routing state or alternatively 
Preset 0 can be recalled to initialize it at any time.

Sync Reference (Optional)

 – If switching on vertical sync pulse is desired, connect one of the Sync 

Reference connectors to a sync pulse signal (NTSC, PAL or tri-level) using 75 Ohm Coax with BNC 
connectors and the other Sync Reference connector can be used as a pass-through to additional properly 
75 Ohm terminated equipment or a 75 Ohm terminator should be installed.  If the sync reference 
functionality is not used, both connectors can be left unconnected.

RS-232 Serial (Optional)

 – If serial control is desired, using the 

Mascot 

 

 P

  rotocol

, connect a D9 female 

to male straight through cable to a control system, such as a computer.  Use 9600 bps 8N1 as the serial 
configuration and enable local echo to see typed characters.

1.2 Powering Up The Device

This device is not equipped with a power switch and is simply connected to the power supply adapter which is 

Page 7 of 55

Copyright © 2013-2015 Matrix Switch Corporation

www.matrix-switch.tv

Содержание MSC-1HD1616L

Страница 1: ...rix Switch Corporation MSC 1HD1616L Product Manual 1RU 16 input 16 output 3G SDI Video Router with Button Control Panel Revision 1 2 Page 1 of 55 2013 2015 Matrix Switch Corporation www matrix switch...

Страница 2: ...IMITED TO ITS CONDITION QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corp...

Страница 3: ...6 24 Updated External Button Control Pinout section Added External Button Control information for MSC HD42L 2014 03 17 Fixed some document cross references Minor text content and figure position chang...

Страница 4: ...Routing Tab 14 2 2 1 Changing a connection 15 2 2 2 Loading a preset 15 2 3 Presets Tab 15 2 3 1 Loading Work Matrix from a source target 16 2 3 2 Saving Work Matrix to a target 16 2 3 3 Usage scenari...

Страница 5: ...PanelExtEn Command 37 3 32 PanelRate Command 37 3 33 PClr Command 38 3 34 PsetNames Command 38 3 35 PSub Command 39 3 36 PView Command 39 3 37 Reboot Command 40 3 38 ReclkDis Command 40 3 39 RemoteSyn...

Страница 6: ...mware 50 4 3 2 Downgrading from version 5 4 0 to a previous version 51 5 Troubleshooting 52 5 1 Unknown IP address 52 5 2 No Ethernet link when connected to network switch 52 5 3 Unexpected reboots 52...

Страница 7: ...nd 2 97 Gbit s will be passed through without re clocking or jitter reduction Adaptive cable equalization on each input can equalize input signals from Belden type 1694A cables up to lengths of 120m 3...

Страница 8: ...r input button The 1st input button pressed selects the source of the primary level The 2nd input button pressed will become the secondary audio source and will flash indicating a breakaway 1 4 Web Pa...

Страница 9: ...section for assistance with developing a network plan for multi device applications 1 4 3 Matrix Routing The Routing tab of the Web Page Interface provides a convenient way to view and change the mat...

Страница 10: ...t still being a fixed IP for each device Consult your DHCP server documentation for information on assigning IP addresses by MAC address if this option is chosen All devices which need to communicate...

Страница 11: ...MSC 1HD1616L Product Manual subsequent sections Page 11 of 55 Copyright 2013 2015 Matrix Switch Corporation www matrix switch tv...

Страница 12: ...ote panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router to control Video only and an additional 16x16 remote panel to control A...

Страница 13: ...aster to provide 3D support Devices must have the same matrix size Resulting 3D matrix is equal to the matrix size of a single device for example two 8x8 routers would result in one 8x8 3D router One...

Страница 14: ...es to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 System...

Страница 15: ...estination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the Load...

Страница 16: ...Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab...

Страница 17: ...s for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to use...

Страница 18: ...tive name of the system up to 15 characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by al...

Страница 19: ...ion to control individual destinations of a 16x4 Router 16 source 4 destination Another usage scenario would be to have 2 separate panels control different levels of a Video Audio Router Control Mode...

Страница 20: ...Command Tab Figure 5 provides access to the Mascot protocol interface Commands are typed on the Command text entry line followed by pressing the Enter key to execute them The results will be displaye...

Страница 21: ...l changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot...

Страница 22: ...should be on in order to see what is typed Pressing the Enter key once connected should yield the prompt character 3 4 Command format Commands consist of a command name zero or more arguments separat...

Страница 23: ...0xNN where NN are 2 hex digits from 0 9 A F or a f Double quoted One or more characters surrounded by double quotes An Argument Single quoted One or more characters surrounded by single quotes An Argu...

Страница 24: ...des This following table shows possible error codes which may be returned in response to commands Error Message Description E01 Token too long A command name or string argument was too long E02 Invali...

Страница 25: ...a preset X DEST SRC LEVEL Perform a matrix connect operation Router systems and MSC GCP2U32 LCD panel only 3 9 Advanced command reference These additional commands consist of those which are not as co...

Страница 26: ...C LVL1 LVL2 Query or assign button panel destination source offsets and levels to control Useful for configuring multiple panels to control different I O regions of a router PanelRate 2 1 RATE Set rem...

Страница 27: ...ery all destination names DestNames DEST Query destination names for all levels of a given destination DestNames DEST LEVEL Query the name of a specific destination and level DestNames DEST LEVEL LABE...

Страница 28: ...ription DHCP Query DHCP enable DHCP 0 1 Set DHCP enable 0 to disable 1 to enable Examples to query and then enable DHCP DHCP 0 DHCP 1 3 14 E Command Routers and MSC GCP2U32 only Query or assign matrix...

Страница 29: ...control the Router device itself This setting is saved and recalled on power up Command Description FrameIP Query IP address of remote Router system to control FrameIP IP Set IP address of remote Rou...

Страница 30: ...rying and assigning the IP address IP 192 168 2 60 IP 192 168 2 61 3 20 LockStatus Command Routers only Query the video lock status and video rate of a Video Router s outputs This command is only supp...

Страница 31: ...ing table Flag Information Fields in JSON data 1 Return names Destination Source and Preset destNames srcNames and psetNames 2 Return matrix routing state state 4 Return preset routing data psetData T...

Страница 32: ...x is OK updating from a remote router for example one or more remote routers disconnected or a general error remote router in error status for example respectively NAME Descriptive name of a level des...

Страница 33: ...d Carina Series routers only Protocol Version 2 4 Query or assign I O grouping This setting is saved and recalled on power up The I O grouping feature is used to combine multiple inputs and outputs Co...

Страница 34: ...twork configuration Maintaining the ability to access a device s web page and for Remote Panel devices to be able to communicate with Routers requires that the IP address is known valid and systems ar...

Страница 35: ...ommand I O pairing is used for pairing destinations sources for 3D support When activated a router will appear to have half the number of physical destinations and sources A given matrix crosspoint ch...

Страница 36: ...determines which destination the button panel starts on 0 is used for no offset default The SRCOFS parameter is used likewise to assign a source offset The LVL1 and LVL2 parameters are used for modify...

Страница 37: ...nal panel interface setting 0 disabled The second command enables the external panel interface 3 32 PanelRate Command Protocol Version 2 1 For changing remote button panel refresh rate When a button p...

Страница 38: ...d MSC GCP2U32 only Query or assign preset names Preset names are stored and recalled on power up Command Description PsetNames Query all preset names PsetNames PRESET Query a single preset name PsetNa...

Страница 39: ...and MSC GCP2U32 only View presets Displays the content of one or all presets The format of the returned output is 1 S1 S2 2 S1 S2 where the 1 and 2 are incrementing destination values followed by one...

Страница 40: ...ms Usually used for creating a 3D matrix from two router systems which will result in one router controlling the left 3D channels and the other router controlling the right channels When enabled this...

Страница 41: ...ich has a 2nd level break away which is routed from source 4 3 41 Sierra Command Carina Series routers only Protocol Version 2 4 Queries or assigns Sierra Video Systems protocol on serial port This se...

Страница 42: ...ames 1 2 AudSrc1 SrcNames 1 2 The first 3 example commands are query commands The last assigns an empty string to the second level of the first source thereby indicating that the first level label sho...

Страница 43: ...would be received on a Carina series system with older firmware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 45 Vars Command Protocol...

Страница 44: ...power cycles Command Description W PRESET Write current matrix routing state to PRESET Example to save state to preset 1 W 1 3 47 WebPass Command Assign a web password to password protect the web page...

Страница 45: ...alue 0 can be used for SRC to Mute a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing stat...

Страница 46: ...the TFTP transfer has to occur within this period after power cycling the device This means the PC needs to be in close proximity of the device remote power control be possible or coordination with so...

Страница 47: ...me IP network as the device if not already Make sure that there are no IP conflicts with the PC or device 3 Prepare the TFTP program to transfer the firmware file to the device but do not initiate the...

Страница 48: ...mmands to navigate to the folder where the firmware file is located 4 Type the following command to prepare the TFTP transfer but don t hit ENTER yet tftp 192 168 2 59 put MatrixFirmware x x x hex 5 M...

Страница 49: ...type quit and ENTER and start over from step 3 4 2 4 Linux The tftp application can easily be installed with your distributions package manager from a terminal below are some example commands for vari...

Страница 50: ...system s settings will not be retained after the software update This means that all input output labels networking configuration and the Ethernet MAC address will be lost and will need to be re enter...

Страница 51: ...ngrading from version 5 4 0 to a previous version If downgrading from Carina firmware version 5 4 0 or newer to a version prior to 5 4 0 the system configuration will not be retained Please contact Ma...

Страница 52: ...inal application once connected and a prompt character should be displayed Type the following commands pressing ENTER after each one to get the IP address and netmask ip netmask 5 2 No Ethernet link w...

Страница 53: ...75 Ohms 1 Cable equalization 1694A coax 400m SD 140m HD 120m 3G Output Level 800 mV P P 5 Output Impedance 75 Ohms 1 Output Jitter 0 2 UI Reference Signal Connector Type Analog BNC with pass through...

Страница 54: ...audio means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled zero o...

Страница 55: ...erial Authorization RMA number which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or mo...

Отзывы: