![Matrix Orbital VK204-25 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/matrix-orbital/vk204-25/vk204-25_technical-manual_1741157011.webp)
complies with the EIA-232 standard in that it uses signal levels from +/- 3V to +/- 12V. It will not operate
correctly at TTL (0 to +5V) levels.
Table 4: RS-232 Pinout
Pin Number
Direction
Description VFD Host
2
Data from VFD
Data out
Tx
Rx
3
Data to VFD
Data in
Rx
Tx
5
-
Ground
gnd
gnd
2.1.5 Configuring RS-232 and I
2
C
RS-232 baud rate and I
2
C address are configured by means of jumpers.
Figure 9: RS-232 Jumpers
The module is supplied with jumpers J1 and J2 installed, which gives an RS-232 baud rate of 19200 and
an I
2
C address of 0x5C.
•
RS-232 port: J0, J1, J2 - control baud rate. RS-232 format is 8N1 (8 bits, no parity, one stop bit)
•
I
2
C port: J0, J1, J2, J3 - sets slave peripheral address
Matrix Orbital