Trouble Shooting

Problem

Cause and Remedy

The Green LED does not light 

when AC power supplied

• Check the AC line is properly connected to the smoke alarm.

• Ensure that the AC power is turned on.

The Red LED does not flash every 

40s

• Ensure that the battery and the AC power are properly connected.

Smoke alarm does not sound 

when tested

• Ensure that the battery and the AC power are properly connected.

• Clean the smoke alarm. Then take out the battery and turn off the       

AC power. Install battery and turn on the AC power after 3 minutes.

Low battery warning

• Ensure that the battery is properly connected.

• Replace a flash battery, refer to “Replace Battery” section.

Fault warning

• Clean smoke alarm. Take out the battery and turn off the AC power. 

Wait 3 minutes, then install battery and turn on the AC power.

Self-test fault warning

• Press the TEST button at least 15s, then release.

False alarm

• Press the HUSH button to silence it.

• Clean smoke alarm device.

• Move the smoke alarm device to new location.

The alarm sounds different from it 

is used to

• Ensure that the battery is not low voltage.

• Clean smoke alarm. Take out the battery and turn off the AC power. 

Wait for 3 minutes, then install battery and turn on the AC power.

The alarm can’t interconnection 

alarm

• Check the Active, Neutral, Interconnection wires are properly 

connected.

• Check the interconnected smoke alarm are supplied from the same 

circuit.

If the problem still exists, please return to your retailers.

If the unit is out of warranty, please replace another new alarm.

Note: If self-test fault warning is existing, but the product can sound alarm when press 

test button. The product can continue to be used. Need to test weekly by press the test 

button instead of self-test weekly.

Содержание FSA-60000

Страница 1: ...Current 100mA Interconnecting Max 24 alarms wired 150m maximum Operating Temperature 0 C to 40 C Ambient Humidity 93 Alarm Sensitivity 0 118 0 169 dB m Alarm Volume 85dB A 3m Sound Pattern ISO8201 BI...

Страница 2: ...to installation 2 As a minimum smoke alarms should be located between sleeping areas and potential sources of fire such as a kitchen heater or basement In single story homes with one sleeping area an...

Страница 3: ...l mounting plugs See Diagram A 5 Follow wiring details as per Diagram D 6 Attach the base to the mounting plugs and fix screws into the plugs See Diagram B 7 Close the alarm body See Diagram C MOUNTIN...

Страница 4: ...seconds The buzzer fault or buzzer detection circuit fault End of life warning The unit chirps between the Red LED flashing twice The unit will send end of life warn ing after 10 years of operation A...

Страница 5: ...smoke alarm Take out the battery and turn off the AC power Wait 3 minutes then install battery and turn on the AC power Self test fault warning Press the TEST button at least 15s then release False al...

Страница 6: ...the red LED will extinguish after 8 seconds and unit will beep 3 times in quick succession The red LED will then flash twice quickly every 8 seconds This indicates that while the module has been recog...

Страница 7: ...5 A fire drill at least every six months including drills at nights Practice allows you to test your plan before an emergency You may not be able to reach your children It is important that they know...

Отзывы: