INSTALLATION

 

   

1. Always isolate mains power prior to installation.

2. Remove cover by turning anti-clockwise and remove the 2 screws as shown in Fig 1.

3. Use the base to mark the drill holes on the mounting surface.

4. Drill holes and insert wall plugs if required.

6. Connect the power wire and the load wire to the connection terminal according

     to the electrical connection Fig 2. Do not exceed the max rated load.

7. Replace & secure base cover, calibrate (Fig 3) and replace front cover.

fig.1

fig.2

fig.3

fig.1

fig.2

fig.3

Important:

1. This microwave sensor cannot penetrate through metal objects.

2. For reliable operation, avoid installing in areas with notable air turbulence or ceiling movement 

N  L'  L

Fig. 1

Fig. 2

Fig. 3

ELECTRICAL CONNECTION (FIG 2)

Connect N and L with power

Connect N and L1 to the load

All electrical installations must be carried out by a suitably qualified and registered electrician