background image

Content

Delay Time

Settings

Display

position

5

0.2S

7

0.4S

9

0.6S

11

0.8S

13

1.0S

Delay

time

Display

position

5

Grind

model

7

Low

9

Mid

11

High

13

Max

Status

5, 7, 9, 11, 13
Long press "SHADE" button for 2S to shift between 2 modes

Switch into sensitivity mode 5 position, goggle enters into Grind mode and stay in 

DIN4 light state and not darken

When the volume of battery is less than 2.4V, LOWBAT indicator will turn red.

Power on: Press the "ON" button once, then the LED light blinks 5 times and it 

enters standby mode.
Manually off: Press the button lasting 2S, when the LOWBAT light is on, then release 

the button.
Automatically off: Goggle will automatically turn off after 10 minutes in inactive mode

Sensitivity

Settings

Shade

Settings

Grinding

Settings

Power

On/Off

Low Volume

Alarm

Function

Button

DELAY

SENS

SENS

ON

BATT

SHADE

3

2

SPECIFICATIONS

Model
View Area
Cartridge Size
Cover Lens Size
UV/IR Protection
Light State
Optical Class

Dark State

Delay Time

Sensitivity

Power On/Off

Sensors
Grinding
Sensitivity Control

Delay Control
TIG Rating
Battery Type
Operating Temperature
Storage Temperature

WG3000/WG3000S
111 x 42mm
196 x 212 x 92mm
158 x 58.6 x 1.0mm
DIN 13
DIN 4
1/1/1/2
External variable shade #5, #7, #9, #11, #13

Mode 1: #5, #7  |  Mode 2: #9, #11, #13 (long press the "shade" button from

Mode 1 to Mode 2)
5 adjustments by button from fast to slow (0.2S, 0.4S, 0.6S, 0.8S, 1.0S)
5 adjustments by button from low to high (Grind mode in position 5. Welding

mode from low to high sensitivity in position 7, 9, 11, 13)

Manually on/manually long press "power" button for 2 seconds or automatically

shut off after 10min in inactive mode.
2
Yes (when sensitivity button is in position 5)
Yes
Yes
>5 AMPS
Replaceable CR2450 lithium batteries
-5˚C ~ +55˚C
-20˚C ~ +70˚C

1
2
3
4
5
6

Cover Lens
Arc Sensor
Rubber Lining
Auto-Darkening Filter I
Digital Control Panel
Elastic Headband

PART #

DESCRIPTION

• Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling 

long, possibly unknown paths and causing electric shock and fire hazards.

• Never use arc welder to thaw frozen pipes.
• Remove electrode from holder when not in use.
• Wear oil-free protective garments such as leather gloves, heavy shirt, cuff-less trousers, high shoes, and a cap.
• Remove any combustibles such as lighters or matches from your person before doing any welding.

FLYING METAL CAN INJURE EYES

• Wear ANSI approved safety glasses with side shields under your welding goggles.
• Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw

off slag.

HOT PARTS CAN CAUSE SEVERE BURNS

• Never touch hot parts bare handed.
• Allow adequate cooling period before touching work piece.

NOISE CAN DAMAGE HEARING

• Noise from some processes or equipment can damage hearing.
• Wear approved ear protection if noise level is high.

GENERAL INFORMATION

• WG3000/WG3000S Welding Goggles do not protect against severe impact hazards such as fractured grinding 

wheels or abrasive disks, explosive devices, or corrosive liquids. Machine guards or eye splash protection must be 

used when these hazards are present.

• The auto-darkening welding filters are designed for arc welding or cutting applications. The unit is suitable for all arc 

welding processes such as MIG, MAG, TIG, SMAW, Plasma, Arc, and Carbon arc.

• This auto-darkening welding filter is not recommended for overhead welding applications, laser welding, or laser 

cutting applications.

• In the event of electronic failure the welder remains protected against UV and IR radiation according to shade 11.
• The auto-darkening welding filter should always be used with the original or OEM replacement cover lenses.
• The manufacturer is not responsible for any failure due to modifications to the welding filter or the use of the filter 

from any other manufacturer’s helmet.

• If protection levels are not common to different parts of the protective equipment, the lower protection level shall 

be assigned.

1

2

4

2

5

6

3

NOTE:

1. Protectors which exhibit broken parts, distortion, or excessive scratches on the lens are unsuitable for use and shall 

not be worn.

2. User shall make a visual inspection of their protector prior to each use.
3. Eye and face protectors that have been subject to an impact shall not be used and shall be discarded and replaced.

OPERATION:
BEFORE WELDING

1. Please verify whether the protection film of exterior and interior glasses has been removed.
2. Please make sure that battery is full of charge if it has not been used for a long time.
3. Please verify whether display of ADF is normal if it has not been used for a long time.
4. Please verify whether solar cell is damaged or blocked by dust, and whether arc sensor is clean.
5. Please check all operating parts to see whether they are worn off or damaged. Any scratched or broken parts should 

be replaced immediately so as not to incur personal injury.

6. The welding hood must be worn underneath the welding goggles and mask.
7. Please verify strap tightness before each use.
8. Please choose the right shade number according to the types of welding machines and current of welding.

DIGITAL CONTROL PANEL

Содержание WG3000

Страница 1: ...fumes if welded Work in a confined space only if it is well ventilated or while wearing an air supplies respirator Always have a trained watchperson nearby Welding fumes and gases can displace air and lower the oxygen level causing injury or death Be sure the breathing air is safe ARC RAYS CAN BURN EYES Never look at arc welding without proper eye protection Arc rays from the welding process produ...

Страница 2: ...es Welding chipping wire brushing and grinding cause sparks and flying metal As welds cool they can throw off slag HOT PARTS CAN CAUSE SEVERE BURNS Never touch hot parts bare handed Allow adequate cooling period before touching work piece NOISE CAN DAMAGE HEARING Noise from some processes or equipment can damage hearing Wear approved ear protection if noise level is high GENERAL INFORMATION WG3000...

Страница 3: ... suitable to most indoor and outdoor welding operations CELL REPLACEMENT When the BAT indicator lights up in red please change battery at once and please pay attention to positive and negative terminals and replace battery according to following operations See Fig 4 1 Unscrew the screw with a Phillips head screwdriver 2 Open the cover plate 3 Change the battery 4 Close cover plate 5 Secure the cov...

Страница 4: ...un ocular de respaldo adecuado LEA LAS INSTRUCCIONES CON DETENIMIENTO ANTES DE USAR Y SÍGALAS ANTES DEL USO INICIAL GAFAS DIGITALES PARA SOLDAR INSTRUCCIONES DE SEGURIDAD IMPORTANTES La soldadura puede producir humo y gases peligrosos para la salud Aleje su cabeza del humo No respire el humo Si está en interiores ventile el área o use un escape en el arco para eliminar el humo y los gases de la so...

Страница 5: ...ebidamente preparados de acuerdo con los estándares AWS F4 1 Conecte el cable de trabajo a la zona de trabajo lo más cerca posible del área de soldadura para evitar que la corriente de soldadura se desplace demasiado posiblemente por rutas desconocidas y provoque descargas eléctricas y riesgos de incendio Nunca use una soldadora de arco para descongelar tuberías congeladas Retire el electrodo del ...

Страница 6: ...n 13 es adecuada para soldar con corriente baja y en un lugar más oscuro en especial para soldaduras por arco de argón de corriente baja 3 La selección de la posición 7 9 u 11 es adecuada para la mayoría de las operaciones de soldadura en interiores y exteriores REEMPLAZO DE CELDAS Cuando el indicador BAT se ilumine en rojo cambie la batería de inmediato y preste atención a los terminales positivo...

Страница 7: ...se puede aplicar contra partículas de alta velocidad a temperatura ambiente MANTENIMIENTO 1 Utilice pañuelos descartables papel para limpiar lentes o un paño de algodón limpio y detergente para limpiar el filtro 2 Utilice un detergente neutro para limpiar el armazón de las gafas para soldar y la banda elástica 3 Reemplace con regularidad el protector exterior e interior y la banda elástica 4 No ut...

Страница 8: ...appement près de l arc pour éliminer les émanations et les gaz de soudage Si la ventilation est médiocre utilisez un appareil à adduction d air homologué Lisez les instructions du fabricant concernant les métaux les consommables les revêtements les nettoyants et les dégraissants N effectuez pas de soudage lorsque des activités de dégraissage de nettoyage ou de pulvérisation ont lieu à proximité La...

Страница 9: ...ir DIN 4 et ne s assombrissent pas Lorsque la capacité de la batterie est inférieure à 2 4 V l indicateur LOWBAT devient rouge Mise sous tension appuyez une fois sur le bouton ON marche Le voyant à DEL clignotera cinq fois et il passera en mode veille Arrêt manuel appuyez sur le bouton pendant 2 s Lorsque le voyant LOWBAT batterie faible s allume relâchez le bouton Arrêt automatique les lunettes s...

Страница 10: ...odification aux lunettes de soudage ou à l ADF et ne tentez pas de les réparer Veuillez cesser immédiatement d utiliser l ADF et contacter le revendeur si le filtre ne s assombrit pas lors du soudage N utilisez pas d alcool d essence ou de diluants pour nettoyer l ADF Ne mettez pas le boîtier de l ADF dans l eau La réaction des cristaux liquides de l ADF sera plus lente si la température ambiante ...

Страница 11: ... est pas défini correctement Ajustez l éclairage Réinitialisez le numéro de teinte Nettoyez ou remplacez le protecteur Retirez le film protecteur Essuyez les deux côtés de la lentille du filtre DÉPANNAGE Le Lunettes de Soudage est couvert par une garantie d un an Cette garantie couvre les défauts du fabricant et de fabrication La garantie exclut les problèmes découlant d un mauvais usage d une uti...

Страница 12: ...23 22 NOTES NOTAS REMARQUES NOTES NOTAS REMARQUES ...

Отзывы: