Replacing the UV plunger lamp
1. Remove the plug from the socket and wait for at least 1 minute.
2. Carefully take the UV plunger out of the water.
3. Loosen the cable gland (
F
) from the nut part (
C
).
4. Take a new UV lamp (
D
) from the packaging.
5. Carefully pull the lamp (
D
) from the lamp fitting (
E
).
6. Carefully slide the new lamp (
D
) into the quartz glass (
A
).
7. Place the lamp fitting (
E
) onto the lamp (
D
).
8. If necessary, clean the quartz glass with a soft cloth and a non-aggressive cleaning agent.
9. Slide the quartz glass into the lamp fitting and hand-tighten the nut onto the screw part (
F
).
10. Please make sure all connector / fittings are thread tighten.
11. The UV-C device is now ready for use.
Attention: the lamp must be disposed of at the civic amenity site of your
municipality. The complete electrical unit of the device must be replaced as a
whole if there is any damage to the power cable.
Technical specifications
Model
40W
75W
Lamp T5
40 Watt
75 Watt
Lamp Interval [hour]
9000 hour
9000 hour
Voltage
115V60Hz / 230V50Hz
Max. Suggested
Pond size
5,500 Gal
21,000L
10,500 Gal
39,700L