background image

þ
þ
þ

energy

bulbs

.co.uk

Mon-Fri:

 8:30am - 6:30pm  

|  Sat & Sun:

 11am - 5pm

08

00 0

43 8

97

8

or 0121 250 2180

Quick 

O

rder Hotline

G

uaranteed Low Prices

Huge Stock Available
Mastervolt Stockist

 

 

 

 
 
 

USER’S AND INSTALLATION MANUAL / GEBRUIKERS- EN INSTALLATIEHANDLEIDING 

BEDIENUNGS- UND INSTALLATIONSANLEITUNG / MANUEL UTILISATEURS ET D’INSTALLATION  

MANUAL DEL USUARIO Y DE INSTALACIÓN / MANUALE DI USO E MANUTENZIONE 

 

 

Sunmaster    

XS4300/ XS3200/ XS2000 

 

Grid connected solar inverter 

 

 

MASTERVOLT 
Snijdersbergweg 93,  
1105 AN Amsterdam 
The Netherlands 
Tel.: +31-20-3422100 
Fax.: +31-20-6971006 
www.mastervolt.com 

Copyright © 2011 Mastervolt, v1.2 October 2011 

ENGLISH:   

PAGE 1

NEDERLANDS:  PAGINA 33 

DEUTSCH: 

SEITE 61 

FRANÇAIS: 

PAGINA 89 

CASTELLANO:  PÁGINA 117 

ITALIANO: 

PÁGINA 145

energybulbs

.co.uk

energybulbs

.co.uk

Содержание Sunmaster XS2000

Страница 1: ...UNG MANUEL UTILISATEURS ET D INSTALLATION MANUAL DEL USUARIO Y DE INSTALACI N MANUALE DI USO E MANUTENZIONE Sunmaster XS4300 XS3200 XS2000 Grid connected solar inverter MASTERVOLT Snijdersbergweg 93 1...

Страница 2: ...ion 4 1 2 Use of this manual 4 1 3 Validity of this manual 4 1 4 Guarantee specifications 4 1 5 Liability 4 1 6 Changes to the Sunmaster 4 1 7 Identification label 4 2 SAFETY GUIDELINES AND WARNINGS 5...

Страница 3: ...tandard 10 3 8 2 Connection of more than two strings option 10 3 9 General safety and installation precautions 11 3 10 Things you need for installation 11 4 INSTALLATION 12 4 1 Installation step by st...

Страница 4: ...the manual in a user accessible place This English manual has 32 pages 1 3 VALIDITY OF THIS MANUAL All the specifications provisions and instructions contained in this manual apply solely to the Maste...

Страница 5: ...is danger of gas or dust explosion or potentially flammable products Use of the Sunmaster other than as mentioned under 2 2 is not considered to be consistent with the intended purpose Mastervolt is n...

Страница 6: ...4 7 712 Check from the part number on the type number plate whether the Sunmaster is appropriate to be used for the intended application refer to table 1 Part number Description DC switch 131004300 XS...

Страница 7: ...stervolt Stockist BEFORE YOU START EN Sunmaster XS4300 3200 2000 October 2011 7 Never expose the Sunmaster to direct weather conditions such as rain snow or wind Install the Sunmaster in a sheltered e...

Страница 8: ...ORE YOU START 8 October 2011 Sunmaster XS4300 3200 2000 EN Do not expose the Sunmaster to humid or dusty environments Keep 10 cm clearance around the Sunmaster When installed next to each other keep a...

Страница 9: ...ng should have double insulation and must be fitted with pre assembled MultiContact connectors 4mm If two or more strings are connected to the same Sunmaster both string lengths must be equal CAUTION...

Страница 10: ...total input power must be distributed equally over both Solar inputs as much as possible See figure 3 2 3 8 2 Connection of more than two strings option In case more than two strings should be connect...

Страница 11: ...or the terminal connections Follow all steps of the installation instructions in order of succession as described The DC switch if installed must stay in the OFF position during the entire installati...

Страница 12: ...gure 4 5 Figure 4 6 5 Insert a flat blade screw driver in the indicated slots b Then remove the bottom plate of the Sunmaster 6 Feed the AC wiring through the left hand cable glad of the bottom plate...

Страница 13: ...ps described below to switch on the Sunmaster 1 Check whether the DC switch of the solar array is still in the OFF position or O position 2 Switch on the AC grid 3 Move the DC switch of the solar arra...

Страница 14: ...by pressing S4 If a wrong country code was entered you can start the procedure over again by pressing S2 and S4 simultaneously during 3 seconds 6 Now the Sunmaster switches on See chapter 0 for opera...

Страница 15: ...lop both plug and socket of the Sunmaster must be replaced 5 2 FORCED COOLING For an optimum internal temperature control the Sunmaster is provided with a cooling fan The cooling fan starts running sl...

Страница 16: ...ay actual readings of the Sunmaster are shown figure 5 3 By pressing S2 Source you can toggle between SOLAR 1 Data measured at DC input SOLAR1 AC GRID Data measured at the AC output of the Sunmaster F...

Страница 17: ...energy revenues When TOTAL is highlighted at the upper side of the LCD display the total performance since commissioning of the Sunmaster is displayed See figure 5 5 By pressing S2 Source you can tog...

Страница 18: ...ERROR LED isn t illuminated no failure is detected the Sunmaster is operating normally If the irradiation of the PV modules is insufficient for instance at night the Sunmaster switches off automatical...

Страница 19: ...he grid or none If inverter 1 fails to provide energy to the grid inverters 2 and 3 halt as well Figure 5 8 shows the display sequence when the first phase fails and starts up again 5 4 MAINTENANCE No...

Страница 20: ...et Select the correct country code See section 4 3 2 On TEMP HI Internal temperature of the inverter is high Maybe the air flow of the Sunmaster is obstructed See chapter 3 3 for installation guidelin...

Страница 21: ...60V DC MPP efficiency 99 9 Fraunhofer algorithm 99 9 Fraunhofer algorithm 99 9 Fraunhofer algorithm Operating voltage range 100 550V DC 100 600V DC 100 450V DC Rated current 15A 15A 11A Start up power...

Страница 22: ...ansients surge varistors MONITORING Indicator Backlit display with indication of power and diagnostic messages External communication 2 galvanic isolated RS485 databus connections External communicati...

Страница 23: ...line Guaranteed Low Prices Huge Stock Available Mastervolt Stockist SPECIFICATIONS EN Sunmaster XS4300 3200 2000 October 2011 23 7 2 OUTLINE DRAWINGS Figure 7 1 Dimensions in mm inch of the Sunmaster...

Страница 24: ...0397100 Data Control Premium II remote Datalogger to monitor up to 6 Sunmaster inverters over the Internet 130397200 Data Control Pro Analogue Datalogger to monitor up to 20 Sunmaster inverters locall...

Страница 25: ...oltage FH high off limit AC frequency FL low off limit AC frequency After each test the user has to confirm the test result before the inverter starts the reclosure count down and reconnects to the gr...

Страница 26: ...TEM MASTERVOLT FH test Actual Red on ACTUAL DAY TOTAL SYSTEM MASTERVOLT ACTUAL DAY TOTAL SYSTEM MASTERVOLT 2 sec 2 sec 2 sec To time display Reclosure time UL test Test time indication Blinking Blinki...

Страница 27: ...Y TOTAL SYSTEM Actual Actual Red on ACTUAL DAY TOTAL SYSTEM ACTUAL DAY TOTAL SYSTEM 2 sec 2 sec 2 sec Reclosure time FL test Test time indication Blinking Blinking Blinking To Time Display Confirm FH...

Страница 28: ...0800 043 8978 or 0121 250 2180 Quick Order Hotline Guaranteed Low Prices Huge Stock Available Mastervolt Stockist CERTIFICATES 28 October 2011 Sunmaster XS4300 3200 2000 EN 10 CERTIFICATES 10 1 CERTI...

Страница 29: ...AN Amsterdam The Netherlands Herewith declares that Product Sunmaster XS4300 Sunmaster XS3200 Sunmaster XS2000 is CE marked and complies with the following standards EMC Directive EMC 89 336 EEG Emis...

Страница 30: ...11am 5pm 0800 043 8978 or 0121 250 2180 Quick Order Hotline Guaranteed Low Prices Huge Stock Available Mastervolt Stockist CERTIFICATES 30 October 2011 Sunmaster XS4300 3200 2000 EN 10 3 AS4777 CERTI...

Страница 31: ...0 Quick Order Hotline Guaranteed Low Prices Huge Stock Available Mastervolt Stockist CERTIFICATES EN Sunmaster XS4300 3200 2000 October 2011 31 n e r g y b u l b s c o u k Snijdersbergweg 93 1105 AN A...

Отзывы: