5 TECHNICAL 

DATA 

 

5.1 SPECIFICATIONS 

 

Model 

SCM20 PWM 

SCM40 PWM 

Article no.: 

131822000 

131824000 

Nominal battery voltage (U

NOM

): 

12V / 24 V (Auto recognition) 

12V / 24 V (Auto recognition) 

 

 

PV-INPUT @ 

U

NOM

 = 12V 

@ U

NOM

 = 24V 

@ U

NOM

 = 12V 

@ U

NOM

 = 24V 

Typical number of cells: 

36 cells 

72 cells 

36 cells 

72 cells 

Absolute maximum PV Voltage: 

28V

DC

 55V

DC

 28V

DC

 55V

DC

 

Maximum PV input current*: 

20A 

20A 

40A 

40A 

Control:  

PWM 

 

 

 

Dusk to dawn threshold voltage: 

5V 

10V 

5V 

10V 

 

 

 

 

 

BATTERY OUTPUT 

@ U

NOM

 = 12V 

@ U

NOM

 = 24V 

@ U

NOM

 = 12V 

@ U

NOM

 = 24V 

Maximum charge current (I

MAX

): 

20A 20A 40A 40A 

Charge voltage, Absorption: 

14.4V  

28.8V 

14.4V 

28.8V 

Charge voltage, Float (flooded): 

13.25V  

26.5V 

13.25V  

26.5V 

Charge voltage, Float (AGM / gel batteries): 

13.8V  

27.6V 

13.8V  

27.6V 

Battery temperature compensation: 

–30 mV/°C 

–60 mV/°C 

–30 mV/°C 

–60 mV/°C 

DC consumption (at night):  

7mA 7mA 7mA 7mA 

Battery voltage operating window: 

10.0-15.0V 20.0-30.0V 10.0-15.0V 20.0-30.0V 

Charge algorithm: 

Three step (Bulk, Absorption, Float) 

Battery types*:  

Flooded, AGM, Gel 

 

 

LOAD OUTPUT 

@ U

NOM

 = 12V 

@ U

NOM

 = 24V 

@ U

NOM

 = 12V 

@ U

NOM

 = 24V 

Maximum output current: 

20A 

20A 

40A 

40A 

Under voltage disconnect (adjustable**): 

10.8~11.8V 21.6~23.6V 10.8~11.8V 21.6~23.6V 

Under voltage reconnect (adjustable**): 

11.6~12.6V 23.2~25.2V 11.6~12.6V 23.2~25.2V 

 

 

 

 

 

GENERAL  

Galvanic isolation between PV and battery: 

No, common negative conductor 

Dimensions in mm [inch] (h x w x d): 

96 x 189 x 53 mm [3.8 x 7.4 x 2.0 inch]; see also section 5.2 

Weight: 480g 
Operating Temperature Range: 

–20°C 

 T

AMB

 

 +50°C [–4°F 

 T

AMB

 

 122°F] 

Full Power Temperature range: 

–20°C 

 T

AMB

 

 +40°C [–4°F 

 T

AMB

 

 104°F] (no power de-rating) 

Non-operating Temperature range: 

–25°C 

 T

AMB

 

 +75°C [–13°F 

 T

AMB

 

 167°F] (storage temperature) 

Relative Humidity: 

5% to 95% non-condensing 

Protections: 

Reversed polarity, output overload, output short circuit, overheating, 
battery under voltage, battery over voltage 

Protection degree: 

IP23 

MasterBus connectivity: 

No 

Load modes**: 

Always on, Dusk to Dawn, Evening, Manual  

Terminals: 

Screw terminals, max. wire size 16mm

2

 

* Short circuit current of the PV module 

 

** Refer to section 2.6 for configuration 

Specifications are subject to change without prior notice. 
 
 

Содержание SCM20 PWM

Страница 1: ...SOLAR CHARGE MASTER SCM20 PWM SCM40 PWM PWM CONTROLLED PV BATTERY CHARGER EN USER S AND INSTALLATION MANUAL NL DE FR ES https www mastervolt com products solar charge controllers 10000014327 02...

Страница 2: ...r s Manual OVERVIEW 1 MENU button 2 OK button 3 LCD display 4 Casing 5 Heatsink 6 PV input 7 Battery connection 8 Load output 9 Temperature sensor jack 10 Identification label rear side Figure 1 Overv...

Страница 3: ...Load mode 8 3 INSTALLATION 9 3 1 Unpacking 9 3 2 Environment 9 3 3 Wiring and fuses 9 3 4 Specifications of the PV array 10 3 5 Connection of loads 10 3 5 1 Load connected to the Load output 10 3 5 2...

Страница 4: ...ter further in this manual 1 3 USE OF PICTOGRAMS Safety instructions and warnings are marked in this manual and on the product by the following pictograms A procedure circumstance etc which deserves e...

Страница 5: ...base at least once a year Defects such as loose connections burnt wiring etc must be corrected immediately If necessary use a soft clean cloth to clean the casing of the Solar Chargemaster Do not use...

Страница 6: ...rolling through a selection of screens Manual Scrolling Mode Press OK shortly to scroll through all screens manually Static Display Mode Hold MENU and OK pressed simultaneously for 1 second to lock th...

Страница 7: ...serious damage to your batteries and or the connected load Adjustments of settings may be undertaken by authorised personnel only If your Solar Chargemaster is not new you have to take into account th...

Страница 8: ...6V 12 6 V 25 2V Dynamic Low voltage disconnect function Indication Disconnect threshold Reconnect threshold at full load at no load 11 0V 22 0V 11 6V 23 2V 12 4 V 24 8V 11 1V 22 2V 11 6V 23 2V 12 5 V...

Страница 9: ...ly complies with all applicable EMC limits it may still cause harmful interference to radio communication equipment If such interference appears it is recommended to increase the separation between th...

Страница 10: ...pical installation diagram The Load output is provided with a protection circuit that switches off the connected load automatically in case of overload or if the battery voltage is too low This kind o...

Страница 11: ...trate the general placement of the Solar Chargemaster in a circuit They are not meant to provide detailed wiring instructions for any particular electrical installation Battery temperature sensor BATT...

Страница 12: ...ential If grounding is required always do this on the negative wires Use one grounding point only NOTE If the battery temperature remains within 15 25 C connection of the battery temperature sensor is...

Страница 13: ...er and the load 5 Check with a suitable voltage meter whether the Battery connection and the LOAD output of the Solar Chargemaster are voltage free 6 Disconnect the negative cable to the PV array from...

Страница 14: ...harge battery voltage is too high 15 5 31 0V Check batteries Check other charging systems Use the battery temperature sensor Over temperature Check cooling of the Solar Chargemaster No battery chargin...

Страница 15: ...lk Absorption Float Battery types Flooded AGM Gel LOAD OUTPUT UNOM 12V UNOM 24V UNOM 12V UNOM 24V Maximum output current 20A 20A 40A 40A Under voltage disconnect adjustable 10 8 11 8V 21 6 23 6V 10 8...

Страница 16: ...ous 150A peak load 77020200 DC Distribution 500 The Mastervolt DC Distribution offers fused DC connections to install up to four different devices Mastervolt can offer a wide range of products for you...

Отзывы: