Mastervolt MasterBus - Inverter Interface Скачать руководство пользователя страница 2

 
 
 
 
 
 

 

 

 

2

 

June 2008 / MasterBus-Inverter Interface / EN 

 

1 GENERAL 

INFORMATION 

 

1.1 

Use of this manual 

This manual serves as a guideline for the safe and 
effective operation of the Inverter Interface. 
 
Keep this manual at a secure place! 
 

1.2 

Guarantee specifications  

Mastervolt guarantees that this product was built 
according to the legally applicable standards and 
stipulations. If you fail to act in accordance with the 
regulations, instructions and stipulations in this 
user’s manual, damage can occur and/or the 
product will not fulfil the specifications. This may 
mean that the guarantee will become null and void. 
 

IMPORTANT: Additional warranty agreements, like 
“Mastervolt system warranty” may contain 
restrictions which forbid resetting of historical data 
The standard guarantee period is two years after 
date of purchase. 
 

1.3 Liability 

 

Mastervolt can accept no liability for: 

x

  consequential damage due to use of the Inverter 

Interface;  

x

  possible errors in the manuals and the results 

thereof;  

x

  Use that is inconsistent with the purpose of the 

product. 

 

CAUTION! 
Never remove the identification label. 

 

 

2 OPERATION 

 
The Inverter Interface operation is entirely MasterBus based. For information about MasterBus and the MasterBus 
event structure, see 

www.mastervolt.com

 
The table below shows the Inverter Interface MasterBus functions: 
 

Monitoring  

Description 

Factory settings 

Range 

State 

Interface can be switched On or Stand by 

Stand by/ On/ 
Alarm* 

Inverter 

Change the state of the interface 

Stand by 

Stand by/ On 

Configuration  

Description 

Factory settings 

Range 

Language 

Set the Inverter Interface menu language  

English 

See specifications 

Device name 

Any name you wish with 12 characters max 

INT inverter 

12 characters max 

Event 1 Source 

Select an event in the Inverter interface 
Event list to serve as Source. 

Disabled Disabled, 

State, 

Failure mode 

Event 1 Target 

Select a device in your system to serve as a 
Target. 

System dependent 

System dependent 

Event 1 Command 

Select a command in the Target command 
list. 

Target dependent 

Target dependent 

Event 1 Data 

Select the way the Command should act on 
the Source 

See MasterBus 
information 

See MasterBus 
information 

Event 2 - 9 

See Event 1 

 

 

* The alarm state cannot be selected. When the inverter is in alarm, it sends out a signal to the interface. 
 
Described above are the events with the interface as Source. The Inverter Interface can serve as Target too.  
It can be switched On and Standby (State) in the configuration menu of another MasterBus device: 
 

Configuration  

Description 

Factory settings 

Range 

Device Event 
Command 

Select a command in the Inverter interface 
Command list 

Disabled Disabled, 

State 

 

Отзывы: