6.3.4 Configuration

 

 

Below parameters can be changed via the MasterBus network by means of a remote control panel or by means of an interface 
connected to a PC with MasterAdjust software. See applicable user’s manuals for details. 

Value 

Meaning 

Factory setting 

Adjustable. range 

General 

Language 

Language displayed on a MasterBus monitoring device  English 

See specifications 

Product name  

Name of this device. This name will be recognized by 
all devices connected to the MasterBus. 

CHG CM+type* 

0-12 chars 

Output 1 

Name of output 1 in the MasterBus network 

House bank 

12 characters max 

Output 2 

Name of output 2 in the MasterBus network 

Output 2 

12 characters max 

Output 3 

Name of output 3 in the MasterBus network 

Output 3 

12 characters max 

Factory settings 

Button to reset the ChargeMaster to factory settings 

 

 

Charge current 

 

 

 

AC load 

Select the method to reduce the AC input power 

Auto 

Auto, MPC, manual 

Maximum current 

Set the maximum charging current allowed  

Model depend. 

Model dependent 

System 

 

System 

 

System behaviour 

Set the use mode. The ChargeMaster can be 
synchronized with other MasterBus chargers. 

System 
behaviour 

Set the use mode. The 
ChargeMaster can be 
synchronized with other 
MasterBus chargers. 

MasterShunt 

Select the MasterShunt that provides the 
ChargeMaster with battery information.  

MasterShunt 

Select the MasterShunt 
that provides the 
ChargeMaster with battery 
information.  

Bulk 

Bulk voltage 

Bulk voltage 

14.40/28.80V 0-15.50/0-31.00V 

Max. bulk timer 

Maximum bulk timer 

8h 

0-24h 

Min bulk timer 

Minimum bulk timer 

120sec 

0-240sec 

Start bulk timer 

Start bulk timer 

13.25/26.50V 

(read only) 

Absorption 

Abs. voltage 

Absorption voltage 

14.25/28.50V 0-15.50/0-31.00V 

Max absorption 

Maximum absorption timer 

4h 

0-24h 

Min absorption 

Minimum absorption timer  

15min 

0-240min 

Return amps 

Return amps (% of maximum charge current) 

6% 

0-50% 

Return amps tim 

Return amps timer 

30sec 

0-240sec. 

Float settings 

Float voltage 

Float voltage 

13.25/26.50V 0-15.50/0-31.00V 

Forced float vo. 

Forced float voltage  
(Constant voltage charging)  

13.25/26.50V 0-15.50/0-31.00V 

Return to bulk 

Return to bulk voltage 12.80/25.60V 0-15.50/0-31.00V 

Return to bulk 

Return to bulk time delay  

30sec 

0-240sec 

Alarms 

DC high on 

Alarm DC High on  

16.00/32.00V 

0-16.00V0-32.00V 

DC high off 

Alarm DC High off 

15.00/30.00V 

0-16.00V0-32.00V 

DC low on 

Alarm DC low on 

10.00/20.00V 

0-16.00/0-32.00V 

DC low off 

Alarm DC low off 

11.00/22.00V 

0-16.00/0-32.00V 

Alarm delay 

Alarm delay time 

30sec 

0-240sec 

Traction 

Traction Bulk v 

Traction bulk voltage 

+300/+600mV 

(read only) 

Traction Absorpt 

Traction absorption voltage 

+300/+600mV 

(read only) 

Traction absorpt 

Traction absorption timer 

8 hrs 

(read only) 

Equalization 

Equalize voltage 

Equalize voltage float +2.25/+4.50V 

(read 

only) 

Max equalize tim 

Max equalize timer 

480 min 

(read only) 

 

DIP-switches 

Battery type 

Setting for AGM/Gel batteries.  
Off = Wet battery, On = AGM/Gel  

Off  

Off, On** 

Charge algorithm 

12V/24V power supply allowed. Off=no, On=yes 

Off 

Off, On** 

Display mode 

Display off saves batteries. Off=no, On=yes 

Off 

Off, On** 

Содержание CHARGEMASTER 12/35-3

Страница 1: ...5 3 12 50 3 24 20 3 24 30 3 FULL AUTOMATIC BATTERY CHARGER MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www mastervolt com Copyright 2009 Masterv...

Страница 2: ...charging 9 3 4 2 Connection of a second and third battery 9 3 5 Masterbus optional 9 3 6 Maintenance 9 3 7 Failures 9 4 INSTALLATION 10 4 1 Unpacking 10 4 2 Environment 10 4 3 Wiring 10 4 3 1 AC wirin...

Страница 3: ...18 6 3 4 Configuration 19 6 3 5 ChargeMaster 1 event source list ChargeMaster as event source 20 6 3 6 ChargeMaster event target list ChargeMaster as event target 20 7 TROUBLE SHOOTING 21 7 1 Fault f...

Страница 4: ...44020200 ChargeMaster 24 20 3 44020300 ChargeMaster 24 30 3 These models are mentioned as Chargemaster further in this manual For other models see the other manuals available on our website www master...

Страница 5: ...d or disassembled There are no serviceable parts inside the cabinet Take it to a qualified authorized and trained serviceman when service or repair is required Incorrect reassembly may result in a ris...

Страница 6: ...e to batteries Do not exceed the recommended limits of discharge level of your batteries 11 If it is necessary to remove a battery always remove grounded terminal from battery first Make sure all acce...

Страница 7: ...connected to the batteries 3 2 SWITCHING ON STAND BY The Chargemaster is activated by holding the POWER switch pressed for approx 3 seconds The POWER switch will illuminate green The state of charge...

Страница 8: ...C 77 F The duration of this phase depends on the ratio of battery to charger capacity and also on the degree to which the batteries were discharged to begin with CHARGE CURRENT BATTERY VOLTAGE BULK A...

Страница 9: ...nt See also section 8 4 for detailed characteristics of the three step Plus charge system 3 4 1 Temperature compensated charging By installing the battery temperature sensor the charge voltages are au...

Страница 10: ...4 3 WIRING AND BATTERIES WARNING The wire and fuse sizes stated in this manual are given as example only Prescribed wire and fuse sizes may be different due to local applicable regulations and standar...

Страница 11: ...l Chargemaster Minimum required battery capacity 12 35 3 70 350Ah 12 50 3 100 500Ah 24 20 3 50 250Ah 24 30 3 70 350Ah 4 3 4 AC safety grounding WARNING The ground wire offers protection only if the ca...

Страница 12: ...ire diameter depend on the electrical installation see section 4 3 1 We recommend as a minimum tool kit Socket wrench 10mm to fix the DC input battery cables Flat blade screw driver 1 0 x 4 0 mm to fi...

Страница 13: ...te the general placement of the Chargemaster in a circuit It is not meant to provide detailed wiring instructions for any particular electrical installation Figure 6 installation drawing of the Charge...

Страница 14: ...ready for operation After switching on the AC power supply the Chargemaster will initiate the charging process 4 8 2 MasterBus During first commissioning the Chargemaster will be recognized by the Mas...

Страница 15: ...will stay on when Chargemaster is switched to stand by mode Note that the display is powered by the batteries ON 5 1 4 DIP switch 4 Equalize mode WARNING Incorrect use of the equalize mode may lead t...

Страница 16: ...and less installation time For central monitoring and control of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glanc...

Страница 17: ...UTP patch cables Mastervolt can supply these cables These cables are also commonly available at computer supply stores OK As with all high speed data networks MasterBus needs a terminating device on...

Страница 18: ...C input frequency is too low 45Hz n a High frequency AC input frequency input is too high 65Hz n a High temperature Internal temperature is too high 70 C 176 F n a Low temperature Internal temperature...

Страница 19: ...attery information Bulk Bulk voltage Bulk voltage 14 40 28 80V 0 15 50 0 31 00V Max bulk timer Maximum bulk timer 8h 0 24h Min bulk timer Minimum bulk timer 120sec 0 240sec Start bulk timer Start bulk...

Страница 20: ...ite of the input Toggle changes the status at the first signal and back at the second signal It is often used in combination with a pulse switch 6 3 5 ChargeMaster 1 event source list ChargeMaster as...

Страница 21: ...ltage Charge current too low See Charge current too low in this table Current to load is too high Reduce load taken from the batteries Charge time too short Use a battery charger with higher capacity...

Страница 22: ...4kg 9Lbs 4kg 9Lbs Recommended battery capacity 70 350Ah 100 500Ah Power factor regulations 0 99 0 99 Temperature compensation Battery temperature sensor and cable included Battery temperature sensor...

Страница 23: ...3x5 2 Weight in kg pound 4kg 9Lbs 4kg 9Lbs Recommended battery capacity 40 200Ah 60 300Ah Power factor regulations 0 99 0 99 Temperature compensation Battery temperature sensor and cable included Bat...

Страница 24: ...TECHNICAL DATA 24 August 2009 Chargemaster1 12 35 3 12 50 3 24 20 3 24 30 3 EN 8 3 DIMENSIONS Figure 14 Dimensions in mm inch...

Страница 25: ...hree step Plus charging method at 25 C 77 F FLOAT ABSORPTION 13 25VDC 2 min 15 min BULK min abs timer min bulk timer BULK Imax Imax 100 Start max bulk timer 13 25VDC 14 40VDC 14 25VDC Bulk Absorption...

Страница 26: ...e equalize charge cycle see section 5 1 3 at 25 C 77 F Figure 18 Temperature compensation characteristic charge voltage versus temperature FLOAT EQUALIZE FLOAT Float voltage 2 25V 15 50VDC Float volta...

Страница 27: ...Touch screen to control and monitor all MasterBus products 77010400 MasterView System Full colour touch screen to control and monitor all MasterBus products 77020100 MasterShunt 500 DC distribution mo...

Страница 28: ...the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonized standards have been applied EN 60950 1 EN 55022 1998 A1 2000 A2 2003 Class A EN 61000 4 2...

Отзывы: