Mastervolt CHARGEMASTER 12/35-3 Скачать руководство пользователя страница 1

 

 

 

 
 
 

USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITUNG 

MANUEL UTILISATEUR / MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO 

 

CHARGEMASTER 1 

12/35-3, 12/50-3, 24/20-3, 24/30-3 

 

FULL AUTOMATIC BATTERY CHARGER 

 

MASTERVOLT 
Snijdersbergweg 93,  
1105 AN Amsterdam 
The Netherlands 
Tel.: +31-20-3422100 
Fax.: +31-20-6971006 
www.mastervolt.com 

Copyright © 2009 Mastervolt v1.3 August 2009 

ENGLISH:   

PAGE 1

NEDERLANDS: PAGINA 

29 

DEUTSCH: SEITE 

57 

FRANÇAIS: PAGINA 

85 

CASTELLANO: PÁGINA 

113 

ITALIANO: PÁGINA 

141

Содержание CHARGEMASTER 12/35-3

Страница 1: ...5 3 12 50 3 24 20 3 24 30 3 FULL AUTOMATIC BATTERY CHARGER MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www mastervolt com Copyright 2009 Masterv...

Страница 2: ...charging 9 3 4 2 Connection of a second and third battery 9 3 5 Masterbus optional 9 3 6 Maintenance 9 3 7 Failures 9 4 INSTALLATION 10 4 1 Unpacking 10 4 2 Environment 10 4 3 Wiring 10 4 3 1 AC wirin...

Страница 3: ...18 6 3 4 Configuration 19 6 3 5 ChargeMaster 1 event source list ChargeMaster as event source 20 6 3 6 ChargeMaster event target list ChargeMaster as event target 20 7 TROUBLE SHOOTING 21 7 1 Fault f...

Страница 4: ...44020200 ChargeMaster 24 20 3 44020300 ChargeMaster 24 30 3 These models are mentioned as Chargemaster further in this manual For other models see the other manuals available on our website www master...

Страница 5: ...d or disassembled There are no serviceable parts inside the cabinet Take it to a qualified authorized and trained serviceman when service or repair is required Incorrect reassembly may result in a ris...

Страница 6: ...e to batteries Do not exceed the recommended limits of discharge level of your batteries 11 If it is necessary to remove a battery always remove grounded terminal from battery first Make sure all acce...

Страница 7: ...connected to the batteries 3 2 SWITCHING ON STAND BY The Chargemaster is activated by holding the POWER switch pressed for approx 3 seconds The POWER switch will illuminate green The state of charge...

Страница 8: ...C 77 F The duration of this phase depends on the ratio of battery to charger capacity and also on the degree to which the batteries were discharged to begin with CHARGE CURRENT BATTERY VOLTAGE BULK A...

Страница 9: ...nt See also section 8 4 for detailed characteristics of the three step Plus charge system 3 4 1 Temperature compensated charging By installing the battery temperature sensor the charge voltages are au...

Страница 10: ...4 3 WIRING AND BATTERIES WARNING The wire and fuse sizes stated in this manual are given as example only Prescribed wire and fuse sizes may be different due to local applicable regulations and standar...

Страница 11: ...l Chargemaster Minimum required battery capacity 12 35 3 70 350Ah 12 50 3 100 500Ah 24 20 3 50 250Ah 24 30 3 70 350Ah 4 3 4 AC safety grounding WARNING The ground wire offers protection only if the ca...

Страница 12: ...ire diameter depend on the electrical installation see section 4 3 1 We recommend as a minimum tool kit Socket wrench 10mm to fix the DC input battery cables Flat blade screw driver 1 0 x 4 0 mm to fi...

Страница 13: ...te the general placement of the Chargemaster in a circuit It is not meant to provide detailed wiring instructions for any particular electrical installation Figure 6 installation drawing of the Charge...

Страница 14: ...ready for operation After switching on the AC power supply the Chargemaster will initiate the charging process 4 8 2 MasterBus During first commissioning the Chargemaster will be recognized by the Mas...

Страница 15: ...will stay on when Chargemaster is switched to stand by mode Note that the display is powered by the batteries ON 5 1 4 DIP switch 4 Equalize mode WARNING Incorrect use of the equalize mode may lead t...

Страница 16: ...and less installation time For central monitoring and control of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glanc...

Страница 17: ...UTP patch cables Mastervolt can supply these cables These cables are also commonly available at computer supply stores OK As with all high speed data networks MasterBus needs a terminating device on...

Страница 18: ...C input frequency is too low 45Hz n a High frequency AC input frequency input is too high 65Hz n a High temperature Internal temperature is too high 70 C 176 F n a Low temperature Internal temperature...

Страница 19: ...attery information Bulk Bulk voltage Bulk voltage 14 40 28 80V 0 15 50 0 31 00V Max bulk timer Maximum bulk timer 8h 0 24h Min bulk timer Minimum bulk timer 120sec 0 240sec Start bulk timer Start bulk...

Страница 20: ...ite of the input Toggle changes the status at the first signal and back at the second signal It is often used in combination with a pulse switch 6 3 5 ChargeMaster 1 event source list ChargeMaster as...

Страница 21: ...ltage Charge current too low See Charge current too low in this table Current to load is too high Reduce load taken from the batteries Charge time too short Use a battery charger with higher capacity...

Страница 22: ...4kg 9Lbs 4kg 9Lbs Recommended battery capacity 70 350Ah 100 500Ah Power factor regulations 0 99 0 99 Temperature compensation Battery temperature sensor and cable included Battery temperature sensor...

Страница 23: ...3x5 2 Weight in kg pound 4kg 9Lbs 4kg 9Lbs Recommended battery capacity 40 200Ah 60 300Ah Power factor regulations 0 99 0 99 Temperature compensation Battery temperature sensor and cable included Bat...

Страница 24: ...TECHNICAL DATA 24 August 2009 Chargemaster1 12 35 3 12 50 3 24 20 3 24 30 3 EN 8 3 DIMENSIONS Figure 14 Dimensions in mm inch...

Страница 25: ...hree step Plus charging method at 25 C 77 F FLOAT ABSORPTION 13 25VDC 2 min 15 min BULK min abs timer min bulk timer BULK Imax Imax 100 Start max bulk timer 13 25VDC 14 40VDC 14 25VDC Bulk Absorption...

Страница 26: ...e equalize charge cycle see section 5 1 3 at 25 C 77 F Figure 18 Temperature compensation characteristic charge voltage versus temperature FLOAT EQUALIZE FLOAT Float voltage 2 25V 15 50VDC Float volta...

Страница 27: ...Touch screen to control and monitor all MasterBus products 77010400 MasterView System Full colour touch screen to control and monitor all MasterBus products 77020100 MasterShunt 500 DC distribution mo...

Страница 28: ...the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonized standards have been applied EN 60950 1 EN 55022 1998 A1 2000 A2 2003 Class A EN 61000 4 2...